Fr-Lu08 Lcd Operation Panel; Appearance And Parts Name; Switching The Main Monitor Data - Mitsubishi Electric FREQROL-CS80 Manual

Hide thumbs Also See for FREQROL-CS80:
Table of Contents

Advertisement

FR-LU08 LCD Operation Panel

• The FR-LU08 is an optional operation panel adopting an LCD panel capable of displaying text and menus.
• Installation of the FR-LU08 on the enclosure surface is possible when using an optional parameter unit connection cable (FR-CB2[ ]).
(To connect the (FR-LU08), an optional operation panel connection connector (FR-ADP) is required.)
• Parameter settings for up to three inverters can be saved.
 Appearance and parts name
(a)
(b)
(j) (k) (l)
(c)
(i)
(h)
(g)
6
 Switching the main monitor data
Pressing
or
displays 6 types of monitor screens in order.
(PREV)
(NEXT)
Hz Out
PREV
Alarm History
1 OHT
2 OV2
3 OV2
PREV
When the fourth monitor screen
is set as the first priority monitor
18
Symbol
a
Power lamp
b
Alarm lamp
c
Monitor
d
FWD key, REV key
(d)
e
STOP/RESET key
(e)
f
Setting dial
(f)
g
PU/EXT key
h
MON key
i
MENU key
j
Software key (F1)
k
Software key (F2)
l
Software key (F3)
Turn ON the power, or press
.
When the first monitor
When the second monitor
screen is set as the first
screen is set as the first
priority monitor screen
priority monitor screen
I Out
1 2 : 3 4
(NEXT)
0.00
Hz
STOP
PU
SET
NEXT
PREV
(PREV)
First monitor
Second monitor
(PREV)
(NEXT)
Set Hz
1 2 : 3 4
4 OV2
7
(PREV)
5 OV2
8
50.00
6 OV3
STOP
PU
NEXT
PREV
CLR
(NEXT)
Faults history monitor
Fourth monitor
(Displayed only when new monitor item
is registered from the Function menu.)
screen
Name
ON when the power is turned ON.
ON when an inverter fault occurs.
Shows a numeric value (readout) of a monitor item such as the
frequency or a parameter number.
(The monitor item can be changed according to the settings of Pr.774 to
Pr.776.)
FWD key: Starts the forward rotation operation.
REV key: Starts the reverse rotation operation.
Stops operation commands.
Used to reset the inverter when the protective function is activated.
Turn the setting dial to change the setting of frequency or parameter, etc.
Press the setting dial to display a fault history number in the fault history
mode.
Switches between the PU operation mode, the PUJOG operation mode,
and the External operation mode.
Shows the first priority monitor screen.
Displays the quick menu.
When this key is pressed while the quick menu is displayed, the function
menu is displayed.
Select a guidance displayed on the monitor.
When the third monitor
screen is set as the first
priority monitor screen
V Out
1 2 : 3 4
(NEXT)
0.00
0.0
A
STOP
PU
STOP
SET
NEXT
T
PREV
SET
(PREV)
Third monitor
(NEXT)
(PREV)
1 2 : 3 4
Hz Out
0.00Hz
(PREV)
I Out
0.00A
Hz
V Out
0.0V
STOP
PU
STOP
SET
NEXT
PREV
SET
(NEXT)
3-line monitor
Description
1 2 : 3 4
V
PU
NEXT
The value of the item set in the
1 2 : 3 4
first priority monitor screen, and
the value of the top two items
among the output current, the
output frequency, and the output
PU
voltage are displayed in rows.
NEXT

Advertisement

Table of Contents
loading

Table of Contents