Option And Peripheral Devices; Option List - Mitsubishi Electric FREQROL-CS80 Manual

Hide thumbs Also See for FREQROL-CS80:
Table of Contents

Advertisement

Option and Peripheral Devices

 Option List
Name
Liquid crystal display operation
panel
Parameter unit (8 languages)
Enclosure surface operation
panel
Parameter unit connection cable
Operation panel connection
connector
DIN rail attachment
AC reactor
EMC Directive compliant noise
filter
EMC compliant EMC filter
installation attachment
Radio noise filter
Line noise filter
Brake unit
Resistor unit
Discharging resistor
Power regeneration common
converter
Stand-alone reactor dedicated for
the FR-CV
High power factor converter
10
Surge voltage suppression filter
Pilot generator
Deviation sensor
Frequency setting potentiometer
Analog frequency meter
×
(64mm
60mm)
Calibration resistor
FR Configurator2
(Inverter setup software)
∗1
The battery (CR1216: a diameter of 12 mm, a hight of 16 mm) is not bundled.
28
Model
FR-LU08
Graphical operation panel with liquid crystal display
FR-PU07
Interactive parameter unit with LCD display
This operation panel enables inverter operation and monitoring of
FR-PA07
frequency, etc. from the enclosure surface
Cable for connection of operation panel or parameter unit
FR-CB20[]
[] indicates a cable length. (1m, 3m, 5m)
A connector to connect the operation panel to the parameter unit
FR-ADP
connection cable.
FR-UDA01, 02
Attachment for installation on DIN rail
For harmonic current reduction and inverter input power factor
FR-HAL
improvement
SF
FR-E5NF
EMC Directive (EN61800-3 C3) compliant noise filter
FR-S5NFSA
For installation of the inverter to the EMC Directive compliant EMC
FR-AAT02
filter (SF).
FR-BIF(H)
For radio noise reduction (connect to the input side)
FR-BSF01
For line noise reduction
FR-BLF
For increasing the braking capability of the inverter (for high-inertia
FR-BU2
load or negative load)
FR-BR
Brake unit, electrical-discharge resistor and resistor unit are used in
GZG, GRZG type
combination
FR-CV
Unit which can return motor-generated braking energy back to the
FR-CVL
power supply in common converter system
The high power factor converter switches the converter section on/off
to reshape an input current waveform into a sine wave, greatly
FR-HC2
suppressing harmonics. (Used in combination with the standard
accessory.)
FR-ASF
Filter for suppressing surge voltage on motor
FR-BMF
QVAH-10
For tracking operation. 70V/35VAC 500Hz (at 2500r/min)
For continuous speed control operation (mechanical deviation
YVGC-500W-NS
detection) Output 90VAC/90°
WA2W 1kΩ
For frequency setting. Wire-wound 2W 1kΩ type B characteristic
Dedicated frequency meter (graduated to 130Hz). Moving-coil type DC
YM206NRI 1mA
ammeter
For frequency meter calibration.
RV24YN 10kΩ
Carbon film type B characteristic
SW1DND-FRC2-E Supports an inverter startup to maintenance.
Applications, Specifications, etc.
∗1
Applicable Inverter
All capacities
All capacities
All capacities
All capacities
All capacities
According to capacities
(excluding inverters FR-
CS84-120 to 295).
According to capacities
According to capacities
FR-CS84-230, 295
All capacities
All capacities
According to capacities
According to capacities
According to capacities
According to capacities
(three-phase 400 V
class only)
According to capacities
(FR-CS84-120 to 295
only)
All capacities

Advertisement

Table of Contents
loading