66297-YIM-C-0205
TABLE 4 -
ELECTRICAL DATA (BASIC UNIT)
VOLTAGE
LIMITATIONS
MODEL
POWER SUP-
BHH
PLY
MIN.
018
208/230-1-60
187
024
208/230-1-60
187
208/230-1-60
187
030
208/230-3-60
187
460-3-60
414
208/230-1-60
187
208/230-3-60
187
036
460-3-60
414
575-3-60
518
208/230-1-60
187
208/230-3-60
187
042
460-3-60
414
575-3-60
518
208/230-1-60
187
208/230-3-60
187
048
460-3-60
414
575-3-60
518
208/230-1-60
187
208/230-3-60
187
060
460-3-60
414
575-3-60
518
1 = Rated in accordance with ARI Standard 110, utilization range "A".
Unitary Products Group
OUTDOOR
COMPRESSOR
FAN
1
MOTOR,
FLA
MAX.
RLA
LRA
253
7.1
48.0
253
9.3
57.0
253
15.0
72.5
253
10.0
63.0
504
5.0
31.0
253
17.2
94.0
253
11.4
78.0
504
5.7
40.0
630
4.7
32.0
253
20.0
104.0
253
13.9
88.0
504
6.4
44.0
630
5.4
34.0
253
23.4
126.0
253
13.0
93.0
504
6.4
46.5
630
5.1
37.2
253
28.8
148.0
253
17.2
123.0
504
8.2
62.0
630
7.0
50.0
2 = Dual element, time delay type.
SUPPLY
AIR
MINIMUM
BLOWER
CIRCUIT
MOTOR,
AMPACITY
FLA
1.1
2.6
12.5
1.1
2.6
15.3
1.1
2.6
22.5
1.1
2.6
16.2
0.6
1.4
8.3
1.1
3.5
26.1
1.1
3.5
18.9
0.6
1.8
9.5
0.4
1.5
7.8
1.1
3.5
29.6
1.1
3.5
22.0
0.6
1.8
10.4
0.4
1.5
8.7
1.5
4.0
34.7
1.5
4.0
21.8
0.8
2.0
10.8
0.6
1.6
8.6
1.5
5.6
43.1
1.5
5.6
28.7
0.8
5.6
16.7
0.6
2.8
12.2
ELECTRIC HEAT
CORRECTION
FACTORS
MAX.
MAX.
FUSE
HACR
UNIT
SIZE,
BREAKER
POWER
SIZE,
FACTOR
AMPS
AMPS
2
15
15
0.96
20
20
0.96
30
30
0.96
25
25
0.96
15
15
0.96
35
35
0.96
25
25
0.96
15
15
0.96
15
15
0.96
40
40
0.96
30
30
0.96
15
15
0.96
15
15
0.96
45
45
0.96
30
30
0.96
15
15
0.96
15
15
0.96
60
60
0.96
40
40
0.96
20
20
0.96
15
15
0.96
NOMINAL VOLTAGE
VOLTAGE
208
240
230
480
460
600
575
TRANSFORMER
SIZE (VA)
40
40
40
75
75
40
75
75
75
40
75
75
75
40
75
75
75
40
75
75
75
KW CAP. MULTI-
PLIER
.75
.92
.92
.92
5