York YCUL0016 User Manual page 24

Air-cooled scroll condensing units
Table of Contents

Advertisement

Ratings -
R22 (English Units)
YCUL0086EC
75°F
SST
(°F)
TONS
KW
EER
TONS
77.9
68.0
12.5
76.1
35.0
80.7
68.7
12.8
78.8
37.0
83.6
69.3
13.2
81.7
39.0
86.6
70.0
13.5
84.6
41.0
89.6
70.7
13.9
87.5
43.0
92.7
71.4
14.2
90.5
45.0
95.9
72.2
14.6
93.6
47.0
99.1
73.0
14.9
96.7
49.0
102.4
73.8
15.2
99.9
51.0
105.7
74.6
15.6
103.2
53.0
109.1
75.5
15.9
106.5
55.0
YCUL0090EC
75°F
SST
(°F)
TONS
KW
EER
TONS
84.2
74.4
12.4
82.1
35.0
87.2
75.2
12.8
85.1
37.0
90.3
76.0
13.1
88.1
39.0
93.5
76.8
13.4
91.2
41.0
96.7
77.6
13.7
94.3
43.0
99.9
78.5
14.1
97.6
45.0
103.3
79.4
14.4
100.8
47.0
106.6
80.4
14.7
104.1
49.0
110.1
81.4
15.0
107.5
51.0
113.6
82.4
15.3
110.9
53.0
117.1
83.4
15.6
114.4
55.0
YCUL0096EC
75°F
SST
(°F)
TONS
KW
EER
TONS
83.7
69.3
12.5
81.7
35.0
86.8
70.1
12.9
84.8
37.0
90.0
70.9
13.2
87.9
39.0
93.3
71.8
13.6
91.1
41.0
96.6
72.6
13.9
94.4
43.0
100.1
73.6
14.2
97.8
45.0
103.6
74.5
14.6
101.3
47.0
107.2
75.5
14.9
104.8
49.0
110.9
76.5
15.3
108.4
51.0
114.7
77.5
15.6
112.2
53.0
118.6
78.6
15.9
116.0
55.0
YCUL0100EC
75°F
SST
(°F)
TONS
KW
EER
TONS
91.0
76.0
12.6
88.8
35.0
94.4
76.9
12.9
92.1
37.0
97.8
77.9
13.2
95.5
39.0
101.3
78.9
13.6
99.0
41.0
104.9
79.9
13.9
102.5
43.0
108.6
81.0
14.2
106.1
45.0
112.4
82.2
14.5
109.8
47.0
116.2
83.4
14.8
113.6
49.0
120.2
84.6
15.1
117.4
51.0
124.2
85.9
15.4
121.4
53.0
128.3
87.3
15.7
125.4
55.0
NOTES:
1. SST = Saturated Suction Temperature
2. kW = Compressors Input Power
3. EER = Condensing Unit EER (includes power from compressors, fans and the control panel)
24
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
71.8
11.6
74.1
75.9
10.8
72.5
11.9
76.9
76.6
11.1
73.2
12.3
79.6
77.2
11.4
73.8
12.6
82.5
77.9
11.7
74.6
12.9
85.3
78.7
12.0
75.3
13.2
88.3
79.4
12.3
76.0
13.6
91.3
80.2
12.6
76.8
13.9
94.3
81.0
12.9
77.6
14.2
97.5
81.8
13.2
78.5
14.5
100.6
82.7
13.5
79.3
14.8
103.9
83.5
13.8
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
78.8
11.5
80.0
83.3
10.7
79.5
11.8
82.9
84.1
10.9
80.3
12.1
85.9
85.0
11.2
81.2
12.4
88.9
85.8
11.5
82.0
12.7
92.0
86.7
11.8
82.9
13.0
95.1
87.6
12.1
83.8
13.3
98.3
88.6
12.4
84.8
13.6
101.5
89.6
12.6
85.8
13.9
104.8
90.6
12.9
86.9
14.2
108.2
91.6
13.2
87.9
14.5
111.6
92.7
13.5
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
72.7
11.7
79.8
76.4
11.0
73.5
12.1
82.8
77.1
11.3
74.3
12.4
85.8
77.9
11.6
75.1
12.7
89.0
78.8
11.9
76.0
13.0
92.2
79.6
12.2
76.9
13.4
95.5
80.5
12.5
77.8
13.7
98.9
81.4
12.9
78.8
14.0
102.4
82.4
13.2
79.8
14.4
105.9
83.4
13.5
80.8
14.7
109.6
84.4
13.8
81.9
15.0
113.3
85.5
14.1
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
79.7
11.8
86.6
83.7
11.0
80.6
12.1
89.9
84.5
11.3
81.5
12.4
93.2
85.4
11.6
82.5
12.7
96.5
86.4
11.9
83.5
13.0
100.0
87.3
12.2
84.5
13.4
103.6
88.3
12.5
85.6
13.7
107.2
89.4
12.8
86.8
14.0
110.9
90.5
13.1
88.0
14.3
114.7
91.7
13.4
89.2
14.6
118.5
92.9
13.7
90.5
14.8
122.4
94.2
14.0
90°F
95°F
TONS
KW
EER
TONS
KW
72.2
80.2
10.0
70.2
84.8
74.8
80.9
10.2
72.8
85.5
77.5
81.6
10.5
75.4
86.3
80.3
82.4
10.8
78.1
87.0
83.1
83.1
11.1
80.8
87.8
86.0
83.9
11.4
83.6
88.6
88.9
84.6
11.7
86.5
89.4
91.9
85.5
12.0
89.4
90.2
94.9
86.3
12.2
92.3
91.1
98.0
87.2
12.5
95.4
91.9
101.2
88.0
12.8
98.4
92.8
90°F
95°F
TONS
KW
EER
TONS
KW
77.9
88.2
9.8
75.7
93.2
80.7
89.0
10.1
78.5
94.1
83.6
89.9
10.4
81.3
95.0
86.5
90.8
10.6
84.1
95.9
89.6
91.7
10.9
87.1
96.9
92.6
92.6
11.2
90.1
97.9
95.7
93.6
11.4
93.1
98.9
98.9
94.6
11.7
96.2
99.9
102.1
95.6
12.0
99.3
101.0
105.4
96.7
12.2
102.5
102.1
108.7
97.8
12.5
105.8
103.2
90°F
95°F
TONS
KW
EER
TONS
KW
77.8
80.3
10.3
75.8
84.4
80.7
81.1
10.5
78.6
85.2
83.7
81.9
10.8
81.6
86.1
86.8
82.7
11.1
84.6
86.9
89.9
83.5
11.4
87.7
87.7
93.2
84.4
11.7
90.8
88.6
96.5
85.3
12.0
94.1
89.5
99.9
86.3
12.3
97.4
90.5
103.4
87.3
12.6
100.8
91.5
106.9
88.3
12.9
104.3
92.5
110.6
89.4
13.3
107.9
93.5
90°F
95°F
TONS
KW
EER
TONS
KW
84.4
87.9
10.3
82.2
92.3
87.6
88.8
10.6
85.3
93.2
90.8
89.6
10.8
88.4
94.2
94.1
90.6
11.1
91.7
95.1
97.5
91.5
11.4
95.0
96.0
101.0
92.5
11.7
98.4
97.0
104.5
93.6
12.0
101.8
98.1
108.2
94.7
12.3
105.4
99.2
111.8
95.8
12.6
109.0
100.3
115.6
97.0
12.9
112.7
101.4
119.5
98.3
13.1
116.5
102.7
100°F
EER
TONS
KW
EER
9.2
68.1
89.6
8.5
9.5
70.6
90.4
8.7
9.7
73.2
91.2
9.0
10.0
75.8
92.0
9.2
10.3
78.5
92.8
9.5
10.5
81.2
93.5
9.7
10.8
84.0
94.4
10.0
11.1
86.8
95.2
10.2
11.3
89.7
96.1
10.5
11.6
92.6
97.0
10.7
11.9
95.6
97.9
11.0
100°F
EER
TONS
KW
EER
9.1
73.5
98.5
8.4
9.3
76.2
99.4
8.6
9.6
78.9
100.4
8.8
9.8
81.7
101.4
9.1
10.1
84.5
102.4
9.3
10.3
87.4
103.4
9.5
10.6
90.4
104.4
9.8
10.8
93.4
105.5
10.0
11.1
96.5
106.6
10.2
11.3
99.6
107.8
10.4
11.5
102.7
108.9
10.7
100°F
EER
TONS
KW
EER
9.5
73.7
88.9
8.9
9.8
76.5
89.7
9.1
10.1
79.4
90.5
9.4
10.4
82.3
91.4
9.7
10.7
85.3
92.3
9.9
11.0
88.5
93.1
10.2
11.3
91.6
94.1
10.5
11.5
94.9
95.0
10.8
11.8
98.2
96.0
11.0
12.1
101.6
97.0
11.3
12.4
105.1
98.1
11.6
100°F
EER
TONS
KW
EER
9.6
79.9
97.1
8.9
9.8
83.0
98.0
9.1
10.1
86.1
98.9
9.4
10.4
89.2
99.9
9.7
10.7
92.4
100.9
9.9
10.9
95.8
101.9
10.2
11.2
99.1
103.0
10.5
11.5
102.6
104.0
10.7
11.8
106.2
105.1
11.0
12.1
109.8
106.3
11.3
12.3
113.5
107.5
11.5
YORK INTERNATIONAL

Advertisement

Table of Contents
loading

Table of Contents