York YCUL0016 User Manual page 22

Air-cooled scroll condensing units
Table of Contents

Advertisement

Ratings -
R22 (English Units)
YCUL0060EC
SST
75°F
(°F)
TONS
KW
EER
TONS
52.2
45.7
12.2
51.0
35.0
54.1
46.1
12.6
52.9
37.0
56.1
46.5
12.9
54.8
39.0
58.1
47.0
13.3
56.7
41.0
60.1
47.4
13.6
58.7
43.0
62.2
47.9
13.9
60.8
45.0
64.3
48.4
14.3
62.8
47.0
66.5
48.9
14.6
65.0
49.0
68.7
49.5
15.0
67.1
51.0
70.9
50.0
15.3
69.3
53.0
73.2
50.6
15.6
71.5
55.0
YCUL0066EC
SST
75°F
(°F)
TONS
KW
EER
TONS
57.6
47.7
13.0
56.2
35.0
59.7
48.1
13.3
58.3
37.0
61.8
48.6
13.7
60.4
39.0
64.0
49.0
14.1
62.6
41.0
66.2
49.5
14.4
64.7
43.0
68.5
50.0
14.8
67.0
45.0
70.8
50.6
15.1
69.2
47.0
73.2
51.1
15.5
71.6
49.0
75.6
51.7
15.8
73.9
51.0
78.0
52.3
16.2
76.3
53.0
80.5
52.9
16.5
78.7
55.0
YCUL0076EC
SST
75°F
(°F)
TONS
KW
EER
TONS
64.2
55.4
12.4
62.6
35.0
66.6
55.9
12.7
64.9
37.0
69.0
56.3
13.1
67.3
39.0
71.4
56.8
13.5
69.7
41.0
74.0
57.3
13.8
72.2
43.0
76.6
57.8
14.2
74.7
45.0
79.2
58.4
14.6
77.3
47.0
81.9
58.9
15.0
79.9
49.0
84.6
59.5
15.3
82.6
51.0
87.4
60.1
15.7
85.3
53.0
90.3
60.7
16.1
88.1
55.0
YCUL0080EC
SST
75°F
(°F)
TONS
KW
EER
TONS
71.4
61.3
12.6
69.8
35.0
74.1
61.8
13.0
72.4
37.0
76.8
62.3
13.3
75.0
39.0
79.6
62.9
13.7
77.7
41.0
82.4
63.4
14.1
80.5
43.0
85.3
64.0
14.5
83.3
45.0
88.3
64.6
14.8
86.2
47.0
91.4
65.2
15.2
89.2
49.0
94.5
65.8
15.6
92.2
51.0
97.6
66.4
16.0
95.3
53.0
100.9
67.1
16.4
98.4
55.0
NOTES:
1. SST = Saturated Suction Temperature
2. kW = Compressors Input Power
3. EER = Condensing Unit EER (includes power from compressors, fans and the control panel)
22
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
48.2
11.4
49.7
50.9
10.6
48.6
11.7
51.6
51.3
10.9
49.1
12.0
53.4
51.8
11.2
49.5
12.4
55.4
52.2
11.5
50.0
12.7
57.3
52.7
11.8
50.4
13.0
59.3
53.2
12.1
50.9
13.3
61.3
53.6
12.4
51.4
13.7
63.4
54.2
12.7
52.0
14.0
65.5
54.7
13.0
52.5
14.3
67.6
55.2
13.3
53.1
14.6
69.8
55.8
13.6
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
50.4
12.1
54.9
53.3
11.2
50.8
12.4
56.9
53.7
11.5
51.3
12.7
59.0
54.2
11.8
51.7
13.1
61.1
54.7
12.2
52.2
13.4
63.2
55.1
12.5
52.7
13.8
65.4
55.7
12.8
53.3
14.1
67.7
56.2
13.1
53.8
14.5
69.9
56.7
13.5
54.4
14.8
72.2
57.3
13.8
55.0
15.1
74.6
57.9
14.1
55.6
15.4
77.0
58.6
14.4
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
58.6
11.5
61.0
61.9
10.7
59.0
11.8
63.3
62.4
11.0
59.5
12.2
65.6
62.8
11.3
60.0
12.5
67.9
63.4
11.6
60.5
12.9
70.3
63.9
11.9
61.0
13.2
72.8
64.4
12.3
61.5
13.6
75.3
64.9
12.6
62.1
13.9
77.9
65.5
12.9
62.6
14.3
80.5
66.1
13.3
63.2
14.6
83.1
66.6
13.6
63.8
15.0
85.8
67.3
13.9
AIR TEMPERATURE ON CONDENSER (°F)
80°F
85°F
KW
EER
TONS
KW
EER
64.6
11.7
68.1
68.1
10.9
65.1
12.1
70.6
68.6
11.2
65.6
12.4
73.2
69.2
11.6
66.2
12.8
75.8
69.8
11.9
66.7
13.1
78.5
70.3
12.2
67.3
13.5
81.3
70.9
12.6
67.9
13.9
84.1
71.4
12.9
68.5
14.2
87.0
72.0
13.2
69.1
14.6
89.9
72.6
13.6
69.7
14.9
92.9
73.3
13.9
70.3
15.3
96.0
73.9
14.3
90°F
95°F
TONS
KW
EER
TONS
KW
48.5
53.8
9.8
47.1
56.8
50.3
54.2
10.1
48.9
57.3
52.1
54.7
10.4
50.7
57.7
53.9
55.1
10.7
52.5
58.2
55.8
55.6
11.0
54.3
58.7
57.8
56.1
11.2
56.2
59.2
59.8
56.6
11.5
58.2
59.7
61.8
57.1
11.8
60.1
60.2
63.8
57.6
12.1
62.2
60.8
65.9
58.2
12.4
64.2
61.3
68.1
58.8
12.7
66.3
61.9
90°F
95°F
TONS
KW
EER
TONS
KW
53.5
56.3
10.4
52.1
59.6
55.5
56.8
10.7
54.0
60.1
57.5
57.3
11.0
56.0
60.6
59.6
57.8
11.3
58.0
61.1
61.7
58.3
11.6
60.1
61.6
63.8
58.8
11.9
62.2
62.1
66.0
59.3
12.2
64.3
62.6
68.2
59.9
12.5
66.5
63.2
70.5
60.5
12.8
68.7
63.8
72.8
61.1
13.1
71.0
64.4
75.2
61.7
13.4
73.3
65.1
90°F
95°F
TONS
KW
EER
TONS
KW
59.4
65.5
9.9
57.7
69.2
61.6
65.9
10.2
59.8
69.7
63.8
66.4
10.5
62.0
70.2
66.1
67.0
10.8
64.2
70.8
68.5
67.5
11.1
66.5
71.3
70.8
68.0
11.4
68.9
71.9
73.3
68.6
11.7
71.2
72.4
75.8
69.1
12.0
73.6
73.0
78.3
69.7
12.3
76.1
73.6
80.9
70.3
12.6
78.6
74.2
83.5
70.9
12.9
81.2
74.9
90°F
95°F
TONS
KW
EER
TONS
KW
66.4
71.9
10.1
64.5
76.0
68.8
72.5
10.4
66.9
76.6
71.3
73.0
10.7
69.4
77.1
73.9
73.5
11.0
71.9
77.7
76.5
74.1
11.3
74.4
78.2
79.2
74.7
11.7
77.0
78.8
81.9
75.3
12.0
79.7
79.4
84.7
75.9
12.3
82.4
80.1
87.6
76.5
12.6
85.1
80.7
90.5
77.1
12.9
88.0
81.3
93.4
77.8
13.3
90.9
81.9
100°F
EER
TONS
KW
EER
9.1
45.8
60.0
8.4
9.3
47.5
60.5
8.6
9.6
49.2
61.0
8.9
9.9
51.0
61.5
9.1
10.1
52.8
62.0
9.4
10.4
54.7
62.5
9.6
10.7
56.5
63.0
9.9
11.0
58.5
63.5
10.1
11.2
60.4
64.1
10.4
11.5
62.4
64.7
10.7
11.8
64.4
65.3
10.9
100°F
EER
TONS
KW
EER
9.6
50.6
63.0
8.9
9.9
52.5
63.5
9.1
10.2
54.4
64.0
9.4
10.4
56.4
64.5
9.7
10.7
58.4
65.1
9.9
11.0
60.5
65.6
10.2
11.3
62.6
66.2
10.5
11.6
64.7
66.8
10.7
11.9
66.9
67.4
11.0
12.2
69.1
68.0
11.3
12.4
71.3
68.6
11.5
100°F
EER
TONS
KW
EER
9.1
55.9
73.1
8.4
9.4
58.0
73.7
8.6
9.7
60.1
74.2
8.9
9.9
62.3
74.8
9.2
10.2
64.5
75.4
9.4
10.5
66.8
75.9
9.7
10.8
69.1
76.5
10.0
11.1
71.5
77.1
10.2
11.4
73.9
77.7
10.5
11.6
76.3
78.4
10.8
11.9
78.8
79.0
11.0
100°F
EER
TONS
KW
EER
9.3
62.6
80.4
8.6
9.6
64.9
80.9
8.9
9.9
67.3
81.5
9.2
10.2
69.7
82.1
9.4
10.5
72.2
82.7
9.7
10.8
74.8
83.2
10.0
11.1
77.4
83.8
10.2
11.4
80.0
84.4
10.5
11.7
82.7
85.1
10.8
12.0
85.5
85.8
11.1
12.3
88.3
86.4
11.4
YORK INTERNATIONAL

Advertisement

Table of Contents
loading

Table of Contents