SECTION 7 – PARAMETER DESCRIPTIONS AND OPTIONS
TABLE 7-1 – DEFINITIONS
MENU ITEM
ACCUMULATED UNOCCUPIED OVERRIDE TIME
ACTIVE ALARM
ADDRESS
APS DATA
BUILDING PRESSURE SETPOINT
BUILDING STATIC PRESSURE
BUILDING STATIC PRESSURE SENSOR
INSTALLED
COMFORT VENTILATION FOR COOLING
ENABLED
COMFORT VENTILATION FOR HEATING
ENABLED
COMFORT VENTILATION LOWER SETPOINT
COMFORT VENTILATION UPPER SETPOINT
COMP 1 ASCD ACTIVE
COMP 1 ASCD TIMER
COMP 1 MIN RUN TIME
COMP 1 OUTPUT
COMP 1 OVERLOAD SWITCH
COMP 2 ASCD ACTIVE
COMP 2 ASCD TIMER
COMP 2 MIN RUN TIME
JOHNSON CONTROLS
DEFINITION
THIS PARAMETER GIVES THE ACCUMULATED TIME THE UNIT
HAS PLACED IN UNOCCUPIED OVERRIDE MODE.
THIS IDENTIFIES THE NUMBER OF ACTIVE ALARMS PRESENT
THIS PARAMETER IS USED TO SET THE COMMUNICATION
ADDRESS FOR THE UNIT WHEN CONNECTED TO A NETWORK
THIS PARAMETER GIVES THE STATUS OF THE SUPPLY FAN AIR
PROVING SWITCH. 0 = SWITCH OPEN, 1 = SWITCH CLOSED
THIS PARAMETER ESTABLISHES THE BUILDING PRESSURE
SETPOINT FOR THE CONTROL OF BUILDING EXHAUST
OPERATION
THIS PARAMETER GIVES THE CURRENT VALUE OF THE
BUILDING STATIC PRESSURE INPUT
THIS PARAMETER MUST BE TURNED ON TO ENABLE THE USE
OF BUILDING PRESSURE IN THE OPERATION OF THE EXHAUST
FUNCTION
THIS PARAMETER MUST BE TURNED ON TO ENABLED
COMFORT VENTILATION DURING COOLING MODE OPERATION
ON A CONSTANT VOLUME UNIT
THIS PARAMETER MUST BE TURNED ON TO ENABLE COMFORT
VENTILATION DURING HEATING MODE OPERATION ON A
CONSTANT VOLUME UNIT
THIS PARAMETER IS THE LOWER SETPOINT USED BY THE UNIT
CONTROLLER TO DETERMINE WHEN TO SWITCH THE UNIT IN
COMFORT VENTILATION MODE
THIS PARAMETER IS THE UPPER SETPOINT USED BY THE UNIT
CONTROLLER TO DETERMINE WHEN TO SWITCH THE UNIT IN
COMFORT VENTILATION MODE
THIS IS USED TO DETERMINE THE STATUS OF THE OFF CYCLE
TIMER. ON MEANS THE COMPRESSOR 1 IS IN THIS MODE
THIS GIVES THE ACTUAL TIME OF THE OFF CYCLE TIMER FOR
COMPRESSOR 1 IN SECONDS.
THIS GIVES THE ACTUAL TIME OF THE MINIMUM RUN TIME FOR
COMPRESSOR 1 IN SECONDS.
THIS GIVES THE STATUS OF THE BINARY OUTPUT FROM THE
UNIT CONTROLLER TO COMPRESSOR CIRCUIT 1
THIS IS THE STATUS OF THE BINARY INPUT FROM THE
COMPRESSOR OVERLOAD FOR COMPRESSOR SYSTEM 1 TO
THE UNIT CONTROLLER. ON - OKAY, OFF - FAULTED.
THIS IS USED TO DETERMINE THE STATUS OF THE OFF CYCLE
TIMER. ON MEANS THE COMPRESSOR 2 IS IN THIS MODE
THIS GIVES THE ACTUAL TIME OF THE OFF CYCLE TIMER FOR
COMPRESSOR 2 IN SECONDS.
THIS GIVES THE ACTUAL TIME OF THE MINIMUM RUN TIME FOR
COMPRESSOR 2 IN SECONDS.
FORM 100.50-NOM6 (1207)
Continued on next page
141