Side And Bottom Supply Air Blower; Typical Field Wiring Diagram; Performance; Additional Static Resistance - York D2EB030 Technical Manual

Affinity series single package cooling units 2.5 thru 5 ton 8.8 - 9.4 eer export only
Hide thumbs Also See for D2EB030:
Table of Contents

Advertisement

360101-XTG-B-0508
TABLE 8: SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE
Blower
Model No.
Speed
0.1
DEB
Setting
CFM
W
High
-
030
Medium
1080
351
(2.5)
Low
810
261
High
-
036
Medium
1465
531
(3.0)
Low
1316
473
High
-
042
Medium
-
(3.5)
Low
1579
567
High
-
048
Medium
1694
690
(4.0)
Low
1385
520
High
-
060
Medium
2339 1170 2275 1118 2211 1067 2147 1015 2083
(5.0)
Low
1929
940
TABLE 9: ADDITIONAL STATIC RESISTANCE
Description
500
Wet Evaporator Coil
.01
Economizer
.00
Filter/Frame Kit
.01
Electric Heat
.02
Note: 1. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.
2. The pressure thru the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air duct
system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation.
CONTROL WIRING
** =
Minimum wire size of 18 AWG
wire should be used for all field
installed 24 volt wire.
PROGRAMMABLE
THERMOSTAT ONLY
* =
Only required on units with
supplemental electric heat.
POWER WIRING
CONTACTOR
GROUND
REFER TO ELECTRICAL DATA
LUG
TABLES TO SIZE THE DISCON-
NECT SWITCH, WIRING AND
OVERCURRENT PROTECTION.
FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM
Johnson Controls Unitary Products
0.2
0.3
CFM
W
CFM
W
CFM
-
-
-
-
-
1021
341
961
331
902
765
240
-
-
-
-
-
1440
605
1361
1395
512
1325
492
1255
1260
455
1204
438
1148
-
-
-
1728
725
1633
-
1674
614
1590
590
1506
1512
546
1444
525
1377
-
1985
870
1939
850
1897
1662
673
1629
657
1597
1349
510
1312
500
1276
-
-
-
2450 1213 2366 1165 2282 1117 2198 1068 2114 1020 1989 993 1864 967 1739 940
1877
903
1824
867
1772
600
700
800
.01
.01
.02
.00
.00
.01
.02
.02
.02
.03
.03
.03
THERMOSTAT
R
G
Y
W
C
FIELD SUPPLIED
DISCONNECT
External Static Pressure (Inches Water Gauge)
0.4
0.5
0.6
W
CFM
W
CFM
W
-
-
1171
504
1080
486
321
841
305
781
290
-
-
-
-
-
581
1273
555
1185
530
473
1167
446
1079
419
420
1069
396
990
372
697
1527
666
1422
635
567
1400
535
1295
502
504
1282
476
1188
447
830
1813
800
1728
770
640
1542
623
1486
607
490
1235
480
-
963
2019
912
830
1720
793
1667
757
Resistance, IWG
CFM
900
1,000
1,100
.03
.04
.05
.01
.01
.01
.02
.02
.03
.04
.04
.05
UNIT TERMINAL STRIP
**
R
24 VOLT
G
TRANSFORMER
Y
*
W
C
CONTACTOR
THREE
PHASE
POWER
SUPPLY
REFER TO ELECTRICAL DATA
GROUND
TABLES TO SIZE THE DISCON-
LUG
NECT SWITCH, WIRING AND
OVERCURRENT PROTECTION.
0.7
0.8
CFM
W
CFM W CFM W CFM W CFM W
990
468
888
456
786
-
-
-
-
-
-
-
-
-
-
-
1097
504
1004 480
912
992
392
-
-
-
911
348
-
-
-
1317
605
1205 576 1094 547
1190
470
1063 428
-
1093
418
-
-
-
1644
740
1559 707 1474 673 1389 640
1431
590
1336 563 1240 537
-
-
-
-
-
-
1955
860
1854 824 1753 788 1652 752
1615
720
1586 706 1557 691 1528 677
1,200
1,300
1,400
.06
.07
.08
.02
.03
.04
.03
.03
.03
.06
.07
.08
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation
after servicing.
NOTE:
HEAT ANTICIPATOR
SHOULD BE SET AT 0.25
AMPS FOR ALL MODELS
FIELD SUPPLIED
DISCONNECT
0.9
1.0
1.1
444
-
-
-
-
-
-
-
-
-
-
-
-
-
-
456
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1,500
1,600
.09
.09
.05
.06
.04
.05
.09
.10
SINGLE
PHASE
POWER
SUPPLY
11