DANGER: Multiple power cords. The product might be equipped with multiple AC power cords
or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords
and power cables. (L003)
4. Label and disconnect all external cables that are attached to the PCIe adapters.
5. Complete the following steps to place the system in the service position.
Do not pull out or install any drawer or feature if the rack stabilizer brackets are not attached to the
rack. Do not pull out more than one drawer at a time. The rack might become unstable if you pull out
more than one drawer at a time.
a. If not already removed, remove the shipping screws (A) as shown in the following figure by using a
Phillips screwdriver.
b. Release the side latches (B) by pressing them downward as shown in the following figure.
c. Pull out the system (C) as shown in the following figure. Ensure that any cables do not catch or
bind as you pull out the system.
Memory modules for the 9040-MR9 17