Application Information; Shipping Inspection; Pre-Installation Instructions - Goodman ACNF18 Series Installation Instructions Manual

Ceiling mount air handlers
Table of Contents

Advertisement

IDENTIFY ALL THE VARIOUS CUTOFF SWITCHES AND DEVICES THAT
. K
SERVICE THIS UNIT
NOW WHERE THE SWITCH IS THAT WILL CUT OFF
ENERGY TO THE HEATING SYSTEM IN THE EVENT OF OVERHEATING

SHIPPING INSPECTION

Upon receiving the product, inspect it for damage from shipment.
Shipping damage, and subsequent investigation is the responsibility
of the carrier. Verify the model number, specifications, electrical
characteristics, and accessories are correct prior to installation. The
distributor or manufacturer will not accept claims from dealers for
transportation damage or installation of incorrectly shipped units.
CODES & REGULATIONS
This product is designed and manufactured to comply with national
codes. Installation in accordance with such codes and/or prevailing
local codes/regulations is the responsibility of the installer. The
manufacturer assumes no responsibility for equipment installed
in violation of any codes or regulations.
The United States Environmental Protection Agency (EPA) has
issued various regulations regarding the introduction and disposal
of refrigerants. Failure to follow these regulations may harm the
environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. A certified technician
must perform the installation and service of this product. Should
you have any questions please contact the local office of the EPA.
REPLACEMENT PARTS
When reporting shortages or damages, or ordering repair parts,
give the complete product model and serial numbers as stamped
on the product. Replacement parts for this product are available
through your contractor or local distributor. Your nearest distributor
can be located online at https://partner.goodmanmfg.com/ or by
contacting:
CONSUMER AFFAIRS
GOODMAN MANUFACTURING COMPANY, L.P.
7401 SECURITY WAY
HOUSTON, TEXAS 77040
(713) 254-4729

APPLICATION INFORMATION

H
P
P
EAT
UMP
REMATURE
.
R
UNNING THE UNIT WITHOUT
CAN CAUSE PREMATURE UNIT FAILURE
INSTALLED ON ALL HEAT PUMP APPLICATIONS
This ceiling mount air handler is available in cooling capacities of
1.5, 2 and 2.5 nominal tons of cooling with a PSC motor (ACNF18,
ACNF24 and ACNF30) and 2 and 2.5 nominal tons of cooing with a
constant torque (EEM) motor (ACNF25 and ACNF31). Electric heat
models are available in capacities of 0, 5, 6, 8 and 10 kW.
The unit is designed to be installed in a horizontal position above
a dropped ceiling. Do NOT install this unit outside the structure.
These models are designed for INDOOR USE ONLY.

PRE-INSTALLATION INSTRUCTIONS

Carefully read all instructions for the installation prior to installing
product. Make sure each step or procedure is understood and
any special considerations are taken into account before starting
installation. Assemble all tools, hardware and supplies needed to
complete the installation. Some items may need to be purchased
locally. Make sure everything needed to install the product is on
hand before starting.
Before attempting any installation, the following points should be
considered:
Structural strength of supporting members
Clearances and provision for servicing
Power supply and wiring
Air duct connections
Drain facilities and connections
Installation Clearances
Place this unit as close to the space to be air conditioned as possible.
These units are U.L. listed for installations with zero clearance
to combustible materials. If this unit is installed in a removable
ceiling panel, ensure adequate space is available for servicing. Run
ducts as direct as possible to supply and return outlets. Use non-
flammable weatherproof flexible connectors on both supply and
return connections at unit to reduce noise transmission.
Ducting
Duct work should be fabricated by the installing contractor in
accordance with local codes. Use industry manuals such as such as
NESCA (National Environmental Systems Contractors Association,
1501 Wilson Blvd., Arlington, Virginia 22209) as a guide when sizing
and designing the duct system.
To ensure correct system performance, the ductwork is to be sized
to accommodate 375-425 CFM per ton of cooling with the static
pressure not to exceed 0.5" W.C. Inadequate ductwork that restricts
airflow can result in improper performance and compressor or
heater failure.
T
O PREVENT THE RISK OF PROPERTY DAMAGE
MONOXIDE POISONING
DO NOT CONNECT DUCTWORK TO ANY HEAT PRODUCING DEVICE
SUCH AS A FIREPLACE INSERT OR STOVE
2
CAUTION
F
N
AILURE
OTICE
HPSK-1
KIT INSTALLED ON HEAT PUMP
. A HPSK-1
.
,
,
,
EXPLOSION
PERSONAL INJURY
.
KIT MUST BE
,
FIRE
CARBON
,
,
OR DEATH