Optimizing the speaker setting for your listening room (YPAO)
Press 8 ENTER to confirm your selection.
15
The top "SET MENU" screen appears in the OSD.
SET MENU
. ;AUTO SETUP
;MANUAL SETUP
.A;SIGNAL INFO
[ ]/[ ]:Up/Down
[ENTER]:Enter
Press I SET MENU to exit from "SET
16
MENU".
y
If you change speakers, speaker positions, or the layout of your
listening environment, run "AUTO SETUP" again to recalibrate
your system.
■ If an error screen appears
Press 8 k / n / l / h to select "RETRY" or
"EXIT" and then press 8 ENTER.
The following display is an example when "E-9:USER
CANCEL" appears in the OSD.
ERROR
. E-9:USER CANCEL
Don't operate
any function
>RETRY
[
[ ]/[ ]:Select
[ENTER]:Enter
Choices: RETRY, EXIT
• Select "RETRY" to retry the "AUTO SETUP"
procedure.
• Select "EXIT" to exit from the "AUTO SETUP"
procedure.
y
If "E-5:NOISY" appears, "PROCEED" also appears in the
choices. When you select "PROCEED", this unit continues the
measurements and settings, but the settings may not be optimal.
36
En
EXIT
[
■ If "WARNING" appears
When this unit detects potential problems during the
"AUTO SETUP" procedure, "WARNING" appears in the
top result display. Check the warning messages to correct
your speaker settings.
Note
Warnings differ from errors in that warnings do not cancel the
"AUTO SETUP" procedure.
1
Make sure the pointer is pointing at
"WARNING" and then press 8 ENTER to
display the detailed information about the
warning.
The number on the right of "WARNING" indicates
the number of warning messages.
AUTO SETUP
. WARNING(3)
RESULT
SP
DIST: 14.0/17.0ft
LVL : -9.0/+6.5dB
>SET
[ ]/[ ]:Up/Down
[ENTER]:Detail
2
Press 8 l / h repeatedly to toggle between
the warning displays.
WARNING
W-1:OUT OF PHASE
Reverse Channel
FL
CENTER
PL
SL
SBL
[
[ ]/[ ]:Select
[ENTER]:Return
y
• For details about each warning message, see the "AUTO
SETUP" section in "Troubleshooting" on page 120.
• When the corresponding warning message is not
applicable to a speaker, "––" is displayed instead.
• If "SWFR: TOO LOUD" or "SWFR: TOO LOW" appears
in the "W-3: LEVEL ERROR" display, adjust the volume
level of the subwoofer(s).
Press 8 ENTER to return to the top result
3
display.
:
3/4/0.1
CANCEL
--
PR
SR
SBR
[

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx-v863bl - av receiver

Table of Contents