2-15. CONTROLS -
COUNTDOWN
TIMERS (CDT)
(Continued)
Output System (Continued)
1. Press and hold the PROGRAM button for 4 seconds.
2. "SetUP" and "Tech" are displayed.
3. Press a timer button under the word "Tech".
Ex: "Tech"
4
5
Press either 4 or 5.
4. Enter access code 1, 1, 2, 2, 1, 1, 2, 2.
5. "outP test Htr" is displayed.
6. Press the 5 timer button (under "Htr") to turn heat and heat
LED on and off.
7. Press the PROGRAM button to move to the next step, or
press and hold the PROGRAM button to exit programming.
Temperature Calibration
1. Press and hold the PROGRAM button for 4 seconds.
2. "Setup" and "Tech" are displayed.
3. Press a timer button under the word "Tech".
Ex: "Tech"
4
5
Press either 4 or 5.
4. Enter access code 1, 1, 2, 2, 1, 1, 2, 2.
5. "outP test Htr" is displayed.
6. Press the PROGRAM button 3 times until "CAL OFS Hi
Probe 185" is displayed.
7. Press and hold number 1 timer (under "CAL"), while press-
ing the INCREASE and DECREASE buttons and set the
display to match the actual cabinet temperature.
8. Press the PROGRAM button to move to the next step or
press and hold the PROGRAM button to exit programming.
2-17