3.2

Editing files

3.2.1

Editing files in HMI sl

Use a copy of the original file to make specific adjustments.
The original file is stored on the CompactFlash Card in the "Siemens" directory.
Store the modified file in the appropriate folder of the "User" or "OEM" directory.
Note
You need to restart HMI sl for the settings made in the file to take effect.
Requirement
In order to copy files, you need access rights for protection level 1 (password: Machine
manufacturer).
If you want to access the "System data" folder in the data tree, you need access rights for
protection level 0 (password: System)
Copying / inserting / opening a file
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
1.
Select the "Startup" operating area.
2.
Press the "System data" softkey.
The data tree is displayed.
3.
Open the required directory (e.g. CF-Card/Siemens/sinumerik/hmi/cfg)
in the "CF Card" directory under "Siemens".
4.
Position the cursor on the desired file.
5.
Press the "Copy" softkey.
6.
Open the directory to which you wish to save the copied file (e.g.
CF-Card/User/sinumerik/hmi/cfg) in the "CF Card" directory under
"User".
Principles of start-up
3.2 Editing files
15