Canon imageRUNNER ADVANCE C5500 Series Service Manual page 666

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

10-0403
-
A. Operation / B. Cause /
C. Remedy
10-0404
-
A. Operation / B. Cause /
C. Remedy
11-0001
-
A. Operation / B. Cause /
C. Remedy
11-0010
-
A. Operation / B. Cause /
C. Remedy
13-00FF
-
A. Operation / B. Cause /
C. Remedy
13-0100
-
A. Operation / B. Cause /
C. Remedy
31-0010
-
A. Operation / B. Cause /
C. Remedy
31-0020
-
A. Operation / B. Cause /
C. Remedy
31-0030
-
A. Operation / B. Cause /
C. Remedy
31-0040
-
A. Operation / B. Cause /
C. Remedy
Toner Bottle empty alarm (C)
When the Toner Bottle empty was detected
Toner Bottle empty alarm (Bk)
When the Toner Bottle empty was detected
Waste toner alarm
Detected waste toner bottle full.
Near-full state of the Waste Toner Container
Detection of near-full state of the Waste Toner Container
For R&D
For R&D
The configuration of an option controlled by the Main Controller has been changed
A change in configuration of an option such as a change in the configuration of the Fax Board, a
change in the configuration of the Voice Board, or a change in the configuration of the option HDD,
which requires turning OFF and then ON the power, was detected.
Detection condition/timing:At the time of startup only
Remedy:Turn OFF and then ON the main power.
The configuration of an option controlled by the RCON has been changed
Due to a change in the configuration related to the scanner, a change in the hardware configuration
which requires turning OFF and then ON the power was detected.
Detection condition/timing:At the time of startup only
Remedy:Turn OFF and then ON the main power.
The configuration of an option controlled by the DCON has been changed
Due to a change in the configuration related to the printer, a change in the hardware configuration
which requires turning OFF and then ON the power was detected.
Detection condition/timing:At the time of startup only
Remedy:Turn OFF and then ON the main power.
Communication with RTC was not available.
Cause: Communication with RTC could not be established.
Detection condition/timing:
- When a communication error occurred with RTC
Movement/symptom:
- FCOT may become longer.
Measures:
1. Check the connector/cable connected to the J109 Main Switch.
2. Check the Main Switch.
3. Replace the DC Controller PCB.
652
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents