1. Remove the ITB Cleaning Blade Unit [1] and put it on paper.
• 1 Stepped Screw [2]
• 1 Wave Washer [3]
• 1 Blade Alignment Plate [4]
NOTE:
The ITB Cleaning Blade Unit can be removed easily by holding the ends of the 2 screws [1] of the unit.
CAUTION:
Actions after
Replacement:"Adjustment Procedure" on page 433
Installing the ITB Cleaning Blade Unit
■ Preparation
1. Removing the ITB
Unit"Removing the ITB Unit" on page 283
2. Removing the ITB Cleaning
3. Removing the ITB Cleaning Blade
[1]
[2]
1x
[3]
[4]
[1]
Unit"Removing the ITB Cleaning Unit" on page 290
Unit"Removing the ITB Cleaning Blade Unit" on page 292
293
4. Disassembly/Assembly
[1]