spark discharge when you touch the ther-
mostat. This may cause the program to be
lost or the thermostat to display incorrectly.
To correct this, remove the thermostat from
the wall and disconnect the battery. Wait
about two minutes, then reconnect the bat-
tery. The thermostat will revert to the fac-
tory preset program until you reprogram the
thermostat. If you don't want to reprogram
the thermostat immediately, press
until OFF is displayed and replace the ther-
mostat on the wall. Then press
until HEAT, COOL, etc. is displayed, and
press
RUN
to begin the factory preset pro-
PRGM
gram. Or you may reprogram the thermo-
stat, then replace it on the wall.
To prevent further static discharge prob-
lems, touch another object to release static
build-up before touching the thermostat.
See OPERATING YOUR THERMOSTAT.
7. Why won't the setpoint temperature go
to the temperature I want?
The highest heating setpoint temperature
you select must be at least 1 F lower than
the lowest cooling setpoint temperature
SYSTEM
you select (for example, if 70 F is your
SWITCH
lowest selected cooling temperature, you
cannot select a heating temperature any
SYSTEM
higher than 68 F). If such a conflict exists,
SWITCH
you must set the lowest cooling tempera-
ture higher in order to set the heating tem-
perature higher. To set a lower cooling
temperature, you must select a lower heat-
ing temperature. See PROGRAMMING
YOUR THERMOSTAT.