• ADJUSTABLE HEATING AND COOLING
CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.
CAUTION
!
A cooling anticipation setting of less
than 10 may cause decreased com-
pressor life.
To adjust anticipation, press
at the same time. The display will show
HEAT 8 (this is the factory preprogrammed
heating anticipation setting). You may se-
lect any anticipation setting from 4 to 40. If
14
SET
and
ADV
CLOCK
DAY
• LOW BATTERY INDICATOR — The word
the heat cycles are too short, press
increase the cycle time. If the heat cycles
are too long, press
cycle time. To set cooling anticipation, press
SET
and
ADV
at the same time again. The
CLOCK
DAY
display will show COOL 14 (factory prepro-
grammed cooling anticipation). Use
and
TIME
to adjust anticipation. Press
BACK
to return to your program.
BATTERY will flash on the display if the 9
volt alkaline battery is low and should be
replaced.
TIME
to
FWD
TIME
to decrease the
BACK
TIME
FWD
RUN
PRGM