a. Cut the temperature sensor loose from the tie
wrap.
b. Insert the sensor down inside the hose bundle
so it is buried in the insulation and up against
the fluid hoses. Be sure the sensor cable will not
get pulled tight by the hose.
F
. 22
IG
c. Use electrical tape to wrap the hose bundle
from where it connects to the system to the
hose sheath. This insulates and protects the
hose bundle.
3A2776K
ti20274a
F
Connect the Fluid Hose Bundle
to the Mix Manifold
1. Unroll the hose bundle out to the spray area.
2. Systems 262869 and 262943: Connect the 3/4 in.
A and 1/2 in. B hoses to the material inlet ball valves
on the mix manifold. See F
Systems 24W626 and 262945: Change the B side
inlet nipple and connect the 3/4 in. A and 3/4 in. B
hoses to the material inlet ball valves on the mix
manifold. Color code material hoses (green and
blue) with respective color identification on mix
manifold. See F
. 23.
IG
Material Inlets
Flush Inlet
. 23
IG
3. Remove the U-shaped tube connectors only from
the end of the longer set of red and blue tubes. Trim
the excess tubing to fit the one set of the red and
blue tubes fully into the two brass compression
fittings on the aluminum heat circulation plate under
the main manifold. Tighten the compression fittings.
4. Route the purple flush hoses from the manifold
underneath the manifold carriage and connect to
the 1/4 in. flush hose in the hose bundle.
See F
. 23.
IG
5. Use electrical tape to wrap the hose bundle from
where it connects to the system to the hose sheath.
This insulates and protects the hose bundle.
Setup
. 23.
IG