Prepare Level Sensor for
Shipping
NOTICE
To prevent damage to the level sensor probe, do
not ship the feed module with the tanks empty and
the level sensor probe installed. This can cause
the probes to vibrate severely and damage the
level sensor head.
If possible, transport the tanks with at least 12 gallons
(46 liters) of viscous material in the tanks, which is
enough for the material level to be above the probe end
and will prevent the probe from vibrating severely. If the
tanks cannot be shipped with material, perform the
following procedure.
1. Disconnect the 3/4 in. union below the level sensor
head. The level sensor head will be loose but will
not be removed. It is not necessary to remove the
level sensor cable.
F
. 43
IG
3A2776K
2. Use a pliers to grasp the flat on the rod and unscrew
it out of the sensor head.
3. Pull the probe up out of the tank and tape it to the
square tube frame securely to prevent vibration.
4. Replace the 3/4 in. union and level sensor head on
the tank lid. Tighten securely for shipping.
5. After shipment, see Install Level Sensor Probes
on page 23 to re-install.

Prepare Level Sensor for Shipping

57