Setup
Connect the Fluid Hose Bundle
to the System
The system is shipped with a 50 ft (15 m) hose bundle
for connecting the system to the mix manifold.
The bundle contains one 3/4 in. ID A material hose, one
1/2 in. ID B material hose (models 262869, 262945) one
3/4 in. ID B material hose (models 24W626, 262943),
one 1/4 in. ID flush hose, and 1/2 in. OD heated fluid
circulation tubes. The hose bundle is insulated and
wrapped inside a protective sheath which has a Velcro
closure so it can be opened to change hoses.
For models 262869 and 262945, use 1:1 Hose and
Fitting kit 24X461 (supplied with your machine) to
replace the fittings and B side circulation hoses. See
supplied manual 334939 for instructions.
1. Position the hose bundle end with the four loose red
and blue tubes at the machine outlet.
Systems 262869 and 262943: Connect the 3/4 in.
A and 1/2 in. B hoses to the respective material
outlet check valves on the front of the system. See
F
. 19.
IG
Systems 24W626 and 262945: Connect the 3/4 in.
A and 3/4 in. B hoses to the respective material
outlet check valves on the front of the system. See
F
. 19.
IG
F
. 19
IG
24
2. Connect the short purple flush hose from the flush
F
IG
3. Connect the two red tubes in the bundle to the tube
ti20106a
F
IG
4. Locate the temperature sensor with black heat
pump to the 1/4 npsm hose in the bundle. Use the
1/4 in. nipple included with the hose bundle to
connect the hoses. See F
. 20: Flush Pump Connection
tee on the red tube on the front of the machine. Do
the same for the blue tubes. See F
. 21
shrink sheath and a connected cable that is
tie-wrapped to the B heater power cable.
. 20.
IG
ti20272a
. 21.
IG
ti20273a
3A2776K