GEM 4242 Operating Instructions Manual page 19

Devicenet, combi switchbox with integrated pilot valve
Table of Contents

Advertisement

9.4 Assembling the stroke limiter (linear actuator)
7.1
1
2
3
4
7.2
5
Option1
9
8
6
1
Stroke limiter
2
Nut
1)
3
Seal
1)
4
Disc
2)
5
Distance piece
6
Actuator spindle
1) Only available for valves with the NO and DA control functions.
2) Only included in required mounting kits. The design depends on the valve.
www.gemu-group.com
1. Screw distance piece 5 onto/into actuator spindle
6.
2. Move the actuator to the closed position.
3. Insert the O-ring 7.1 in the stroke limiter 1.
4. Insert the O-ring 7.2 in the washer 4.
5. Screw stroke limiter 1 with nut 2, seal 3 and washer
4 into the actuator opening.
6. Set stroke limiter 1 to the required stroke.
5
7. Make sure that the minimum stroke is reached.
8. Secure stroke limiter 1 with nut 2.
Option2
Key
1)
7.1
O-ring
1)
7.2
8
Protective cap
9
Position indicator
10
Operating bush
11
Spindle
12
Travel sensor
19 / 36
9 Assembly and installation
GEMÜ 4242
DeviceNet

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents