Cleaning And Replacing The Plug - Samson 46-5 Mounting And Operating Instructions

Differential pressure limiters with flow limitation, self-operated
Table of Contents

Advertisement

Servicing
NOTICE
!
Risk of regulator damage due to excessively
high or low tightening torques.
Observe the specified torques on tightening
regulator components. Excessively tightened
torques lead to parts wearing out quicker.
Parts that are too loose may cause leakage.
Observe the tightening torques specified in
section 7.3.
Note
The regulator was checked by SAMSON be-
fore it left the factory.
− The product warranty becomes void if ser-
vice or repair work not described in these
instructions is performed without prior
agreement by SAMSON's After-sales Ser-
vice department.
− Only use original spare parts by
SAMSON, which comply with the original
specifications.
7.1 Cleaning and replacing the
plug
See Fig. 2.
Disassembly
1. Put the regulator out of operation (see
section 9.1).
2. For Type 46-6, completely relieve the
tension from the set point spring (8) by
turning the set point adjuster (10) or
manual adjuster (19) counterclockwise
().
32
3. Unscrew the screws (15) and lift the actu-
ator off the valve body.
4. Pull the valve spring (5), if installed, out
of the body.
5. DN 15 to 25: unscrew and pull out the
guide nipple with plug (3) using a socket
wrench (order no. 1280-3001).
DN 32 to 50: unscrew the stopper (25)
at the plug and pull out the plug.
6. Clean the seat and plug thoroughly.
Check the control line for any blockages.
If the plug is damaged, replace the entire
plug with a new one.
Assembly
1. Insert cleaned or new plug.
2. DN 15 to 25: tighten the guide nipple
with plug (3) using a socket wrench (or-
der no. 1280-3001). Observe the tight-
ening torques specified in section 7.3.
DN 32 to 50: insert the plug followed by
the stopper (25) of the plug. Observe the
tightening torques specified in sec-
tion 7.3.
3. Insert the valve spring (5), if installed, in-
to the body.
4. Place the actuator on the body. Tighten
screws (15). Observe the tightening
torques specified in section 7.3.
5. Fasten tight the control line (11).
6. Install the regulator into the pipeline.
7. Put the regulator into operation (see sec-
tion 5.3).