Preparation For Installation - Samson 46-5 Mounting And Operating Instructions

Differential pressure limiters with flow limitation, self-operated
Table of Contents

Advertisement

Storage instructions
− Protect the device against external influ-
ences (e.g. impact).
− Do not damage the corrosion protection
(paint, surface coatings). Repair any
damage immediately.
− Protect the device against moisture and
dirt. Store it at a relative humidity of less
than 75 %. In damp spaces, prevent con-
densation. If necessary, use a drying
agent or heating.
− Make sure that the ambient air is free of
acids or other corrosive media.
− Observe the permissible ambient tem-
peratures (see section 3.3).
− Do not place any objects on the device.
Special storage instructions for elastomers
Elastomer, e.g. diaphragm
− To keep elastomers in shape and to pre-
vent cracking, do not bend them or hang
them up.
− We recommend a storage temperature of
15 °C for elastomers.
− Store elastomers away from lubricants,
chemicals, solutions and fuels.
Tip
SAMSON's After-sales Service department
can provide more detailed storage instruc-
tions on request.
EB 3130 EN

4.4 Preparation for installation

Proceed as follows:
Î Flush the pipelines.
Note
The plant operator is responsible for clean-
ing the pipelines in the plant.
Î Check the regulator to make sure it is
clean.
Î Check the regulator for damage.
Î Check to make sure that the type desig-
nation, valve size, material, pressure rat-
ing and temperature range of the regula-
tor match the plant conditions (size and
pressure rating of the pipeline, medium
temperature, etc.).
Î Check any mounted pressure gauges to
make sure they function.
Measures for preparation
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

46-6

Table of Contents