TROUBLE-SHOOTING CHART
Check this list first before you call for service...
PROBLEM
POSSIBLE CAUSE
1A] Adjustable temperature is
set too high
TEMP
TOO
HOT
2A] Opening door unnecessarily
2B] Temperature is set too low
TEMP
NOT
HOT
ENOUGH
2C] Cord plug pulled out from outlet
2D] Fuse blown - no power to outlet
3A] Cabinet not plugged into outlet
3B] Controls " OFF "
NO HEAT
3C] Fuse Blown - no power to outlet
AT ALL
3D] Heating element burned out*
4A] Low Temperature Alarm
ALARM
BEEPS
NOTE: TAMPERING WITH CONTROL PANEL OR ELECTRICAL COMPONENTS VOIDS FWE WARRANTY.
All units are tested at the factory prior to shipping. Due to conditions in transit, beyond our control, occasionally a control
panel or component may need to be replaced.
* Heating element will either function or not function. Only a slight warmth indicates a problem with the control panel
*
not the element.
REMEDY
1A] Set temperature at a lower temperature
(no lower than 140°F) by turning knob to desired
temperature. A momentary touch of the "Recall
Temp Set Point" key will recall the original dial
setting. The display will then automatically return
to the actual internal cabinet temperature.
2A] Keep door closed and latched shut
as much as possible.
2B] Set temperature at a higher temperature by turning
knob to desired temperature. A momentary touch of
the "Recall Temp Set Point" key will recall the original
dial setting. The display will then automatically return
to the actual internal cabinet temperature.
2C] Replug cord into proper outlet.
2D] Have a qualified electrician check power
and fuse box.
3A] Plug cabinet into properly grounded electrical outlet.
3B] Check to see if Power Indicator Light is lighted.
Press "On/Off" Icon on control panel.
3C] Have a qualified electrician check power
to fuse box.
3D] Unplug cart from electrical source. Remove screws
holding heating element in place. Gently pull
element away from back wall a few inches to
expose wire connections. Disconnect wires, and
replace element with new one. Reconnect wires,
secure element with screws.
4A] Cabinet has dropped below "Set Point" for more than
2 minutes. Acknowledge: Press any key to cancel
beeping and flashing LED. The LED remains lit until
the temperature rises above the alarm set point.
NOTE: THE FACTORY DEFAULT FOR THIS FEATURE
IS IN THE "OFF" OR DISABLED MODE.