Advertisement

Quick Links

OPERATING
INSTRUCTIONS
ORIGINAL INSTRUCTIONS
PHU-12-CIN PROOFER
Caution: Read the
instructions before
INTERNATIONAL
using the machine.
PHU-12-CIN

Advertisement

Table of Contents
loading

Summary of Contents for FWE PHU-12-CIN PROOFER

  • Page 1 OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS PHU-12-CIN PROOFER Caution: Read the instructions before INTERNATIONAL using the machine. PHU-12-CIN...
  • Page 2: Warning Symbols

    FWE PHU-12-CIN PROOFER WARNING SYMBOLS AND EXPLANATIONS WARNING SYMBOLS To indicate hazards arising from dangerous voltages To identify the terminals which, when connected together, bring the various parts of an equipment or of a system to the same potential. To identify the terminal which is intended for...
  • Page 3 FWE PHU-12-CIN PROOFER CASTER WEIGHT CHART AND SERVICE INFORMATION SEE SHIPPING LABEL FOR CASTER SIZE CASTER DESCRIPTION MAX WEIGHT 2” GREY RUBBER CASTER,SWIVEL W/BRK 34Kg CASTER 2” RIGID 68Kg CASTER 3” RIGID 68Kg CASTER 3.5” RIGID HEAVY DUTY 113Kg CASTER 4X2” EZ ROLL RIGID POLYBLUE 272Kg CASTER 5”...
  • Page 4 FWE PHU-12-CIN PROOFER WARNING AND CLEANING CARE CLEANING Keep your cabinet clean by simply wiping the interior and exterior, as needed, with a damp cloth or sponge and a mild soapy solution. NEVER USE ABRASIVES, ACIDS, OR STRONG CLEANERS. Do not flood or allow electrical parts to become wet. The interior tray slide assemblies and humidifier pans are removable for easy cleaning.
  • Page 5 For U.S. and Canada Models: The amperage of your cabinet is stamped on the name plate serial tag attached to the unit. FWE models are equipped with a grounded cord plug for your protection against possible shock hazards. Be sure to plug only into a properly grounded wall receptacle.
  • Page 6 PHU-12-CIN PROOFER Serial Tag Parts List Control Panel Cord Winding Bracket Heat System Tunnel 12″ x 20″ Moisture Drip (305mm x 508mm) Removable Trough with Water Pan Drip Pan Removable Drain Plug Heat Basin FWE PHU-12-CIN PROOFER...
  • Page 7: Control Panel

    FWE PHU-12-CIN PROOFER CONTROL PANEL Press tactile key to Heat Cycling Light alternate between ACTUAL temp Thermometer (with ACTUAL LED illuminated) and SETPOINT temperature. Low Temp Alarm Air Temperature “HEAT” Recommended Control Dial Settings: AIR TEMPERATURE SETTING: 110°F / 43°C...
  • Page 8: Enabling Alarms

    FWE PHU-12-CIN PROOFER ENABLING ALARMS LOW TEMP ALARM OPERATION Unit has a built in “Low Temp Alarm”, allowing the operator to have an audible and a visual indicator that the heated cabinet temperature falls below the "Low Temperature" set point for more than two (2) minutes.
  • Page 9: Installation

    FWE PHU-12-CIN PROOFER INSTALLATION CONGRATULATIONS..and thank you for purchasing an FWE PHU-12-CIN Proofer. Your unit has been designed and manufactured under rigid controls to assure you the most efficient service. It is a full time unit, and may be used continuously.
  • Page 10 FWE PHU-12-CIN PROOFER GENERAL OPERATING INSTRUCTIONS PREPARING THE CABINET BEFORE LOADING FOOD 1) PLUG CABINET INTO A PROPERLY GROUNDED POWER RECEPTACLE. Press the “ / ” rocker switch to the “ ” position. 2) ADD HOT WATER TO THE 12″ x 20″ (305MM X 508MM) PAN.
  • Page 11 FWE PHU-12-CIN PROOFER EASY TO OPERATE Water Pan Heat Basin rocker switch activates power to the Control. PHU-12-CIN is equipped with two (2) heating elements and two (2) separate controls which regulate these elements. This allows you to adjust the temperature and humidity separately.
  • Page 12 FWE PHU-12-CIN PROOFER HEAT SYSTEM AND CABINET COMPONENTS ADDING WATER TO 12″ x 20″ (305MM x 508MM) PAN Add hot water to 12″ x 20″ (305mm x 508mm) pan with heat tunnel in position. Water pan is positioned into heat basin.
  • Page 13 FWE PHU-12-CIN PROOFER DRAIN DRIP TROUGH DRIP TROUGH: DRAIN AS REQUIRED A DRIP TROUGH has been provided to collect excess cabinet moisture or run-off. It is located be- low the door. Drain as often as required. CAUTION: Drain responsibly to keep area and floor...
  • Page 14 FWE PHU-12-CIN PROOFER NOTES Model Number ______________________ Serial Number ______________________ Date of Purchase ____________________ Notes: ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ CAUTION: HOLDING FOOD AT TEMPERATURES OF LESS THAN 140°F (60°C) MAY BE DANGEROUS.
  • Page 15: Limited Two-Year Warranty

    FWE PHU-12-CIN PROOFER LIMITED TWO YEAR WARRANTY FWE / Food Warming Equipment Company, Inc. (Seller) warrants to the original purchaser, subject to the exceptions and conditions below, that FWE manufactured equipment shall be free from defects in material or factory workmanship, under ordinary use for the purpose for which it is designed.
  • Page 16 SERVE REFRIGERATION BARS 5599 HWY. 31 W. Portland, TN 37148 800.222.4393 815.459.7500 Fax: 815.459.7989 www.FWE.com sales@fwe.com Ops-Manual-PHU-12-CIN Proofer R.15.2 © 2015 Food Warming Equipment Co., Inc. Errors subject to correction. All specifications subject to change without notice. Printed in USA.

Table of Contents