Download Print this page

Disassembling The Op3000 Control Panel - DURKOPP ADLER 867-M PREMIUM Additional Instructions

Conversion op3000 to commander basic/pro
Hide thumbs Also See for 867-M PREMIUM:

Advertisement

Conversion
5. Wait until the machine has started and is showing the Manual mode
6. Remove the USB key from the control.
 The software update is complete. The conversion to the Commander

2.2 Disassembling the OP3000 control panel

Fig. 2: Disassembling the OP3000 control panel
(1) - Control panel OP3000
(2) - Cable
(3) - Arm cover
To disassemble the OP3000 control panel:
1. Remove wing screw (5) and threaded pin.
2. Remove control panel OP3000 (1) and the control panel holder (6).
3. Remove the valve cover (4) ( Service Instructions).
4. Remove the arm cover (3) ( Service Instructions).
5. Remove the cable (2) of the OP3000 and pull the plug out of the control.
Additional Instructions 867-M PREMIUM - 03.0 - 10/2018
or Automatic mode.
Basic/Pro control panel can be performed.
(4) - Valve cover
(5) - Wing screw
(6) - Control panel holder
5

Advertisement

loading