Economizer/Ventilation Report

Touch the Economizer/Ventilation Report button to view
the Economizer/Ventilation Report screen. Touch the
arrow buttons to move between screens.
Outdoor Air Damper %
XXX% Open
Ventilation Control
Fixed, DCV
Active Min OA Damper Position Target
XXX%
Active Upper CO2 Limit Setpoint
XXXX PPM
Econ Dry Bulb Enable Setpoint
XXX.X F/C
Return Air Humidity
XXX%
Design Min OA Damper Pos Setpoint 100% Fan
XXX%
DCV Min OA Damper Pos Setpoint 100% Fan
XXX%
DCV Min OA Flow Setpoint
XXXXX CFM / LPM
Outdoor Air Flow
XXXXX CFM/LPM
Exhaust Fan Starts
XXXXXX
Space Pressure
XX.XX IWC /cmWC
Ventilation Override Pressurize Input
Open, Closed
Power Exhaust Fan Output
De-energized, Energized

Compressor Report

Touch the Compressor Report button to view the
Compressor Report screen. Touch the arrow buttons to
move between screens.
Table 4.
Compressor report - data area
Active Cooling Stages
X
Outdoor Fan A Output
Energized, De-energized
Dehumidification Status
Inactive, Active Reheat, Active Enhanced
Compressor 1 Disable Input
Enabled, Disabled
Compressor 1 Proving Input
Open, Closed
20
Clogged Filter Input
Open, Closed
Changeover Switch Input
Cooling, Heating
Data Area
The following data appears in the Economizer/Ventilation
Report screen.
Economizing
Enabled, Disabled
Economizing Enable Type
Dry Bulb, Reference Enthalpy, Comparative
Enthalpy
Manual Enthalpy Override
Enabled, Disabled
Active Lower CO
Limit Setpoint
2
XXXX PPM
Econ Reference Enthalpy Setpoint
XXX.X BTU/lb
Outdoor Air Humidity
XXX%
Design Min OA Damper Pos Setpoint Mid Fan
XXX%
DCV Min OA Damper Pos Setpoint Min Fan
XXX%
Active Min Outdoor Air Flow Target
XXXXX CFM/LPM
Exhaust Fan Running Time
HHHHH:MM
Active Space Pressure Setpoint
XX.XX IWC /cmWC
Ventilation Override Purge Input
Open, Closed
Exhaust Fan Proving Input
Open, Closed
Data Area
The following data appears in the Compressor Report
screen.
Cooling Stages Configured
X
Outdoor Fan B Output
Energized, De-energized
Variable Speed Compressor Volts
XX.X V
Compressor 2 Disable Input
Enabled, Disabled
Compressor 2 Proving Input
Open, Closed
Smoke Detector Input
Open, Closed
Mixed Air Temp
XXX.X F/C
Outdoor Air Temp
XXX.X F/C
Return Air Temp
XXX.X F/C
Space CO
2
XXXX PPM
Local Enthalpy Setpoint
A, B, C, D, E
Design Min OA Damper Pos Setpoint Min Fan
XXX%
Power Exhaust Fan Output
De-energized, Energized
Outdoor Air Flow Adjustment Setpoint
XX.X
Min Outdoor Air Flow Deadband
XXXXX CFM/LPM
Exhaust Damper Position% Open
XXX%
Outdoor Fan A Output
Space Pressure Deadband
XX.XX IWC/cmWC
Ventilation Override Exhaust Input
Open, Closed
Number of Compressors Installed
X
Variable Speed Outdoor Fan %
XXX.X %
Variable Speed Compressor Capacity %
XXX.X %
Compressor 3 Disable Input
Enabled, Disabled
Compressor 3 Proving Input
Open, Closed