Alarm Icons; Sorting Alarms - Trane Tracer TD-5 Installation, Operation And Maintenance Manual

For reliatel controller
Table of Contents

Advertisement

Alarm Icons

Alarms icons appear in the left-most column of the alarms
screen. They are identifiable by their shape and color.
Table 1.
Alarm icons
Active
Alarm Icons
Notification Class
Critical
Service Required
Advisory
Information

Sorting Alarms

To sort alarms by a category other than date and time,
touch one of the other column headings in the table. The
column heading responds by changing to blue, and the
alarms table re-sorts according to the blue column
heading. By touching the blue column heading again, the
column will change the sort direction.
Severity: Alarms are sorted by there notification class
shown in the table above in either descending or
ascending order.
Date and Time (the default sort): Alarms are sorted by
timestamp in either descending or ascending order.
Description: Alarms are sorted alphabetically by
description in either descending or ascending order.
Table 2.
List of alarms
Space Temp Sensor Failure
Compressor 1 HPC Lockout
Comp 1 Disable Input/LPC
Compressor 2 LPC Lockout
Smoke Detector
Dirty Filter
Emergency Stop
Mixed Air Temp Sensor Fail
Return Air Temp Sensor Fail
Coil Temp Sensor #1 Fail
Demand Defrost Fault B
Demand Defrost Fault D
Local Cool Setpoint Fail
Vent Override – Purge
Vent Override – Pressurize
Freezestat Tripped
RT-SVX49C-EN
Outdoor Temp Sensor Fail
Compressor 1 LPC Lockout
Compressor 2 HPC Lockout
Comp 2 Disable Input/LPC
Heat Failure
Supply Fan Failure
Frostat™ Trip
OA Humidity Sensor Failure
Return Air RH Sensor Failure
Demand Defrost Fault A
Demand Defrost Fault C
Defrost Default Mode
Local Heat Setpoint Fail
Vent Override – Exhaust
Drain Pan Overflow
Supply Air Temp Sensor Fail
Table 2.
List of alarms (continued)
CO
Sensor Failure
2
Space Humidity Sensor Fail
Airflow Sensor Fail
Space Pressure Setpoint Fail
Heating High Temp Limit Open
Inducer Proving Switch Fail
Flame Sensed w/Gas Valve Off
Economizer Actuator Fault
SA Reset Amount Failure
SA Temp Heat Setpoint Fail
SA Press Setpoint Fail
Supply Air Press Sensor Fail
SA Pressure PWM Fault
Comp 2 Disable Input/HPC
Exh/Ret Fan Proving Failure
RTEM Comm Fail
RTVM Comm Fail
SA Reheat Setpoint Failure
Space Press Deadband Fail
Ent Evap Temp Sensor Fail
SA Temp Heat Setpoint Fail
Demand Defrost Fault B Ckt 2
Defrost Default Mode Ckt 2
Demand Defrost Fault B Ckt 1
Defrost Default Mode Ckt 1
IGN1 Communications Timed out IGN2 Communications Timed out
DCV Min Position Setpoint Fail (@
Full Fan Speed)
Enthalpy Setpoint Fail
DCV Min Position at Minimum Fan
Speed Fail
DA Cool Setpoint Fail
Compressor 3 HPC Lockout
Comp 3 Disable Input/LPC
BAS Interface Comm Fail
Unit Economizing When It Should
Not Be
Excessive Outdoor Air
VSPD Compressor Drive Fault
Alarms
CO
Setpoint Failure
2
Dehumid Setpoint Failure
Min OA Flow Setpoint Fail
Space Pressure Sensor Fail
Flame Rollout Switch Open
No Flame Sensed on heat call
Gas Heat Module Failure
Morning Warmup Setpoint Fail
SA Temp Cool Setpoint Fail
SA Reset Setpoint Failure
SA Pressure Deadband Fail
SA High Press Limit
Comp 1 Disable Input/HPC
CO2 Low Limit Setpoint Fault
RTOM Comm Fail
RTAM Comm Fail
VSM Comm Fail
RTDM Comm Fail
Mod Dehumid Config
Coil Temp Sensor #2 Fail
Demand Defrost Fault A Ckt 2
Demand Defrost Fault C Ckt 2
Demand Defrost Fault A Ckt 1
Demand Defrost Fault C Ckt 1
Exhaust Fan Setpoint Fail
Design Min Position Setpoint Fail
(@ Full Fan Speed)
Design Min Position at Minimum
Fan Speed Fail
Design Min Position at Midpoint
Fan Speed Fail
PWM Max Fan Spd Setpt Fail
Compressor 3 LPC Lockout
Comp 3 Disable Input/HPC
Unit Not Economizing When It
Should Be
Outdoor Air Damper Not
Modulating
Mixed Air Low Limit Cycle Active
VSPD Compressor Drive Lockout
13