Trane Voyager Commercial Installation, Operation And Maintenance Manual page 11

Packaged rooftop air conditioners with reliatel controls and estage 27.5 to 50 tons - 60 hz, 22.9 to 41.7 tons 81-148 kw - 50 hz
Hide thumbs Also See for Voyager Commercial:
Table of Contents

Advertisement

Miscellaneous Options
Digit 17
0 = No Service Valves
A = Service Valves
Std efficiency units excluding 400/500
std efficiency CV: If Digit 17 = 0, no valves
will be provided. If Digit 17= A, service valves
will be provided in the suction and discharge
lines. High efficiency units including
400/500 std efficiency CV: Digit 17 is not
selectable. Suction and discharge service
valves are included.
Digit 18
B = Through the Base Electrical Provision
Digit 19
C = Non-Fused Disconnect Switch w/ External
Handle
Digit 20
* = Unused Digit
Digit 21
* = Unused Digit
Digit 22
F = Trane Communication Interface (TCI)
Digit 23
G = Ventilation Override
Digit 24
H = Hinged Service Access
Digit 25
H = Condenser Hail Guards
J = Condenser Coil Guards
Digit 26
K = LCI (LonTalk)
B = BACnet Communications Interface (BCI)
Digit 27
0 = 5kA SCCR
D = High Fault 65kA SCCR Disconnect
Digit 28
0 = Standard Drain Pan
M = Stainless Steel Drain Pan
1 = Standard Drain Pan w/ Condensate
Overflow Switch
2 = Stainless Steel Drain Pan w/ Condensate
Overflow Switch
RT-SVX34R-EN
Digit 29 — Efficiency/ Condenser Coil
Options
0 = Standard Efficiency Unit
J = Standard Efficiency Unit with Corrosion
Protected Condenser Coil
K = High Efficiency Unit (eStage)
L = High Efficiency Unit (eStage) with
Corrosion Protected Condenser Coil
Digit 30, 31 — Miscellaneous Options
P = Discharge Temperature Sensor
R = Clogged Filter Switch
Digit 32 — Modulating Hot Gas Reheat
Option
T = Modulating Hot Gas Reheat
Digit 33 — Human Interface
5 = Touchscreen Human Interface, 5 inch
Model Number Notes
Notes:
1.
All voltages are across the line starting
only.
2.
Electric Heat KW ratings are based upon
voltage ratings of 380/415 V. Heaters A,
B, C, D are used with 22.9-29.2 ton (82-
105 kW) units only and heaters B, C, D, E
are used with 33.3-41.7 ton (120-148
kW) units only.
3.
The service digit for each model number
contains 33 digits; all 33 digits must be
referenced.
4.
Ventilation override exhaust mode is not
available for the exhaust fan with fresh
air tracking power exhaust. VOM is
available for the exhaust fan without
fresh air tracking power exhaust.
M M o o d d e e l l N N u u m m b b e e r r D D e e s s c c r r i i p p t t i i o o n n
11