Icom IC-705 Advanced Manual page 209

Hf/vhf/uhf all mode transceiver
Hide thumbs Also See for IC-705:
Table of Contents

Advertisement

15. ABOUT THE DV GATEWAY FUNCTION
Troubleshooting
D Troubleshooting for the Access Point mode operation
Problem
After your call, the repeater
replies "RX" or "RPT?" and the
Access Point call sign and ID
suffix "G."
After your call, the repeater
replies 'RPT?' and the access
repeater's call sign.
"L" appears on the LCD.
"DV" and "FM" icons
alternately blink.
You can transmit, but cannot
receive from the destination
repeater.
Possible Cause
The Remote D-STAR transceiver's
call sign has not been set in the
transceiver.
The Remote D-STAR transceiver's
call sign has not been registered at
a gateway server.
The Terminal/AP call sign that is
set in the transceiver, RS-MS3A, or
RS-MS3W has not been registered
in the RS-RP3C as the access
point.
The destination station's call sign
(UR) has not been registered to the
gateway server, or the registered
contents do not match your
transceiver's setting.
A wrong destination repeater's call
sign is set to "TO."
The transceiver's Internal Gateway
settings or the application software
settings are wrong.
The destination station that uses
the Terminal mode or Access Point
mode does not transmit periodically.
The repeater cannot connect to the
destination repeater.
The repeater is busy.
While receiving through the Internet,
some packets may be lost due to
network error (poor data throughput
performance).
While in the DV mode, an FM signal
is received.
You cannot connect to the Internet,
or Global IP address is not assigned.
The router or mobile router's port is
not correctly forwarded.
The firewall is blocking the
necessary port.
15-25
Solution
Set the Remote transceiver's call
sign in the transceiver.
Register the Remote D-STAR
transceiver's call sign at a
gateway server.
When using the Internal Gateway
function, register the Terminal/
AP call sign that is set in the
transceiver into the RS-RP3C as
the access point.
When using the External Gateway
function, register the Terminal/
AP call sign that is set in the
RS-MS3A or RS-MS3W into the
RS-RP3C as the access point.
Check the destination station's
register information.
Set "TO" to the correct destination
repeater's call sign.
When using the Internal Gateway
function, correctly set the transceiver's
Internal Gateway settings.
When using the External Gateway
function, correctly set the
RS-MS3W or the RS-MS3A.
The destination station makes a
call again.
Wait for a while, and try again.
Wait for a while, and try again.
L When the transceiver receives
corrupted data, and misidentifies it
is as Packet Loss, "L" is displayed.
Use a different operating
frequency until there are no FM
signals on the original frequency.
Check the Internet connection and
Global IP address assignment.
Forward the router or mobile
router's correct port to your device.
Check your firewall settings.
REF�
p. 13-3
p. 13-4
p. 13-4
p. 13-4
p. 15-17
p. 15-10
RS-MS3W,
RS-MS3A's
instruction
manual
p. 15-4
p. 15-4
p. 15-12

Advertisement

Table of Contents
loading

Table of Contents