2. Under the Button Properties menu, change the Mute Control Function setting to Logic out.
MXA310 MicroflexAdvance Command Strings
The device is connected via Ethernet to a control system, such as AMX, Crestron or Extron.
Connection: Ethernet (TCP/IP; select "Client" in the AMX/Crestron program)
Port: 2202
Conventions
The device has 4 types of strings:
GET
SET
REP
SAMPLE
All messages sent and received are ASCII. Note that the level indicators and gain indicators are also in ASCII
Most parameters will send a REPORT command when they change. Thus, it is not necessary to constantly query
parameters. The MXA310 will send a REPORT command when any of these parameters change.
The character
"x"
in all of the following strings represents the channel of the MXA310 and can be ASCII numbers 0 through 5 as in
the following table.
0
1 through 4
5
Command Strings (Common)
Get All
Finds the status of a parameter. After the AMX/Crestron sends a GET command,
the MXA310 responds with a REPORT string
Changes the status of a parameter. After the AMX/Crestron sends a SET com­
mand, the MXA310 will respond with a REPORT string to indicate the new value of
the parameter.
When the MXA310 receives a GET or SET command, it will reply with a REPORT
command to indicate the status of the parameter. REPORT is also sent by the
MXA310 when a parameter is changed on the MXA310 or through the GUI.
Used for metering audio levels.
All channels
Individual channels
Automix output
Shure Incorporated