Crossover Ignition System Operations - Weber SUMMIT 400 Operating Manual

Natural gas barbecues
Hide thumbs Also See for SUMMIT 400:
Table of Contents

Advertisement

MAINTENANCE

Crossover Ignition System Operations

If the Crossover Ignition System fails to ignite the Front
burner, light the Front burner with a match. If the Front
burner lights with a match, then check the Crossover
Ignition System.
Check that both the white and black ignition wires are
attached properly. Figure 17.
Check that the Crossover Ignition button pushes the
igniter (button) down, and returns to the up position.
Check to see if the igniter is loose in the frame.
Tighten if necessary; See Step "Install igniter" for
correct procedure.
If the Crossover Ignition System still fails to light, contact
Weber-Stephen Customer Service.
White wire
Black wire
Figure 17