Tables - Xerox DocuMate 252 Service Manual

Sheetfed scanner
Hide thumbs Also See for DocuMate 252:
Table of Contents

Advertisement

4.2.2 Tables

The tables in this section provide detailed troubleshooting information.
4.2.2.1 The Power LED does not go on
Cause
Unplugged from
outlet
AC power
unplugged at
unit
Power switch is
OFF
AC voltage
failure
Power unit AC
input connector
disconnected
Power switch
connector
disconnected
Power unit-main
PCBA connection
failure
Power unit
output voltage
failure
PCBA Failure
LED board-main
PCBA connection
failure
Relevant Unit
Check Method
None
Visual check
None
Visual check
None
Visual check
None
AC outlet voltage
check
None
Visual check
None
Visual check
None
Visual check
Power unit
Output voltage
(+24V) check
Main control
Tester check
PCBA
(+24V, GND)
LED board
None
Visual check
Table 4.3
4-9
Service Manual
Maintenance
Method
Insert the AC
plug into the
outlet.
Insert the AC
cable into unit.
Turn the power
switch on.
None
Connect the
connector.
Connect the
connector.
Connect the
connector.
Replace the
power unit
Remove the
cause or replace
the PCBA.
Connect the
connector

Advertisement

Table of Contents
loading

This manual is also suitable for:

Documate 262Documate 272

Table of Contents