1. Release the side handle clamping band by turning the handle grip.
2. Slide the side handle clamping band over the chuck from the front and into the recess provided.
3. Set the side handle to the desired position.
4. Tighten the side handle clamping band by turning the handle grip.
5.1.3
Fitting the depth gauge (optional)
1. Release the side handle clamping band by turning the handle grip.
2. Slide the depth gauge from the front into the 2 guide holes provided.
3. Secure the side handle by turning the knob until the clamping band is tight.
5.1.4
Setting the power level
After the battery is inserted, the product is always set by default to full power.
1. Press the "button for half power". The product runs at half power.
▶ The "half power indicator" lights up.
2. Press the "button for half power" again. The product runs at full power.
▶ The "half power indicator" goes out.
5.1.5
Inserting / removing the accessory tool
DANGER
Risk of fire! Risk of contact between the hot accessory tool and highly inflammable materials.
▶ Do not lay the hot accessory tool down on highly inflammable materials.
CAUTION
Risk of injury! The accessory tool gets hot during use.
▶ Wear protective gloves when changing the accessory tool.
▶ Do not place the hot accessory tool on readily flammable materials.
The use of unsuitable grease can cause damage to the product. Use only genuine Hilti grease.
1. Apply a little grease to the connection end of the accessory tool.
▶ Use only genuine Hilti grease. Using the wrong grease can result in damage to the product.
2. Push the accessory tool into the chuck as far as it will go (until it engages).
3. After fitting the accessory tool, grip it and pull it in order to check that it is securely engaged.
▶ The product is ready for use.
4. Pull the chuck ring back as far as it will go and remove the accessory tool.
5.1.6
Inserting the battery
WARNING
Electrical hazard! Risk of short circuiting.
▶ Before inserting the battery, check to ensure that the battery terminals and the contacts on the
combihammer are free from foreign objects.
WARNING
Risk of injury! Hazard presented by a falling battery.
▶ A falling battery may present a risk of injury to yourself and others. Check that the battery is securely
seated in the combihammer.
1. Push the battery into the battery holder until it engages with an audible click.
2. Check that the battery is seated securely.