12000 Scanner

2.7.3 Auxiliary RS232 interface

The auxiliary serial interface is used exclusively for RS232 point-to-point
connections.
The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well
as particular operating modes, such as local echo, can be defined using the
LDHOST utility program or Host Mode programming. For more details refer to
section 2.9 and to the section "Auxiliary Interface Menu" in the LDHOST Help
Online.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary
interface:
Pin
20
21
23
24
7
12000 Scanner
RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 2.22 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the
connected devices. If the RTS/CTS handshaking protocol is enabled, the LazerData
12000 Scanner activates the RTSAUX output to indicate a message is to be
transmitted. The receiving unit activates the CTSAUX input to enable the
transmission.
2.20 - Installation
Name
Function
RXAUX
Auxiliary input
TXAUX
Auxiliary output
CTSAUX
Auxiliary handshake
RTSAUX
Auxiliary handshake
SGND
Signal Ground
USER INTERFACE
20
RXAUX
TXD
21
TXAUX
RXD
23
CTSAUX
DTR
24
RTSAUX
DCD
7
SGND
SGND