The WRONG output is used either for "Verifier" mode or for PCS control (PCS
control is available for DSP models only, see section 1.3). For Verifier this output
activates when the decoded code does not correspond to the one set in the
configuration. For PCS this output activates when the PCS level is below the
threshold value.
12000 Scanner
Figure 2.29 - WRONG code output connection
These outputs are all level or pulse-programmable: a 50-ms pulse is generated in
the second case. Further programming information is supplied in the section
"Output Lines" in the LDHOST Help Online.
2.8

POSITIONING

The LazerData 12000 Scanner is able to decode moving bar code labels at a variety
of angles, however significant angular distortion may degrade reading
performance.
When mounting the LazerData 12000 Scanner, take into consideration these three
ideal label position angles: Pitch 0° , Skew 10° to 30° and Tilt 0°.
Follow the suggestions below for the best orientation:
The Pitch angle is represented by the value P in Figure 2.30. Position the reader in
order to minimize the Pitch angle.
2.24 - Installation
USER INTERFACE
14
WRONG+
15
WRONG-
Installation Manual
Vext 40 Vdc max