2.4.3 Auxiliary RS232 interface

The auxiliary serial interface is used exclusively for RS232 point-to-point
connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as
particular operating modes such as LOCAL ECHO can be defined using the
LDHOST utility program or "Host Mode" programming provided on diskette.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary
interface:
25-Pin
20
21
23
24
7
11000
scanner 25-pin
Figure 2.12 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the
connected devices. If the RTS/CTS handshaking protocol is enabled, the scanner
activates the RTSAUX output to indicate a message is to be transmitted. The
receiving unit activates the CTSAUX input to enable the transmission.
2.12 - Installation
Name
RXAUX
TXAUX
CTSAUX
RTSAUX
SGND
USER INTERFACE
20
RXAUX
21
TXAUX
23
CTSAUX
24
RTSAUX
7
SGND
RTS/CTS HARDWARE HANDSHAKING
Installation Manual
Function
Auxiliary input
Auxiliary output
Auxiliary handshake
Auxiliary handshake
Signal Ground
TXD
RXD
DTR
DCD
SGND