Performance Data; Operating Requirements; California Proposition 65 Warning - Pentair US-1500 Installation And Operating Instructions Manual

Monitored dual filtration system
Table of Contents

Advertisement

PERFORMANCE DATA

Important Notice: Read this performance data and compare
the capabilities of this system with your actual water
treatment needs. It is recommended that, before installing a
water treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 53 for
reduction of the substances listed below. The concentration
of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in
NSF/ANSI 53.
Model US-1500
Maximum
Influent
Permissible
Challenge
Product Water
Substance
Concentration
Concentration
Standard 53
0.15 mg/L ±
Lead (pH 6.5)
0.010 mg/L
10%
0.15 mg/L ±
Lead (pH 8.5)
0.010 mg/L
10%
Chloroform
0.300 mg/L ±
(VOC surrogate
0.015 mg/L
10%
chemical)
Flow Rate=0.5 gpm (1.9 L/min); Capacity=1000 gallons (3785 L) or 12 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Do not use with water that is microbiologically
WARNING:
unsafe or of unknown quality without adequate
disinfection before or after the system.
Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.
Substances reduced are not necessarily in your
NOTE:
water. Filter must be maintained according to
manufacturer's instructions, including replacement
of filter cartridges.
Test Conditions
Flow Rate
= as noted for filter system
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5±1
Temperature
= 68°F ± 5°F (20°C ± 2.5°C)

Operating Requirements

Pressure
= 30-125 psi (2.1–8.62 bar)
Temperature
= 40-100°F (4.4–37.8°C)
8 • PENTAIR
US-1500 Monitored Dual Filtration System Installation and Operating Instructions
Reduction
Minimum
Average
Requirements
Reduction
Reduction
99.3%
98.7%
99.4%
98.3%
97.6%
99.7%
Organic Chemicals Included by Surrogate Testing:
Substance
alachor
atrazine
benzene
carbofuran
carbon tetrachloride
chlorobenzene
chloropicrin
2,4-D
dibromochloropropane (DBCP)
o-dichlorobenzene
p-dichlorobenzene
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
cis-1,3-dichloropropylene
dinoseb
endrin
ethylbenzene
ethylene dibromide (EDB)
haloacetonitriles (HAN):
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloracetonitrile
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
heptachlor
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
lindane
methoxychlor
pentachlorophenol
simazine
styrene
1,1,2,2,-tetrachloroethane
tetrachloroethylene
toluene
2,4,5-TP (silvex)
tribromoacetic acid
1,2,4-trichlorobenzene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
trihalomethanes (includes):
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
xylenes (total)

CALIFORNIA PROPOSITION 65 WARNING

This product contains chemicals known to the
WARNING:
State of California to cause cancer or birth
defects or other reproductive harm.
Maximum permissible
Influent Challenge
product water
Concentration mg/L
concentration mg/L
0.050
0.001
0.100
0.003
0.081
0.001
0.190
0.001
0.078
0.0018
0.077
0.001
0.015
0.0002
0.110
0.0017
0.052
0.00002
0.080
0.001
0.040
0.001
0.088
0.0048
0.083
0.001
0.170
0.0005
0.086
0.001
0.080
0.001
0.079
0.001
0.170
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.25
0.00001
0.0107
0.0002
0.044
0.001
0.060
0.000002
0.055
0.00001
0.050
0.0001
0.096
0.001
0.120
0.004
0.150
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.270
0.0016
0.042
0.001
0.160
0.0005
0.084
0.0046
0.150
0.0005
0.180
0.0010
0.300
0.015
0.070
0.001

Advertisement