Sharp ER-3100 Installation Manual page 62

Hide thumbs Also See for ER-3100:
Table of Contents

Advertisement

Check the mode switch in the SRV mode to see if it functions
normally.
Perform the following key operation:
D
lo6~TL
With this key operation the code that correspondsto the mode
currently selected by the mode switch appears on the register
display. Turn the mode switch to respective positions in the
sequence shown in the table below to see if correspondingmode
codes appear on the display.
11
10
9
8
7
6
5
4
3
2
1
//7/-
/~/~
Y
Y:
Oto 7, 9, E, F
Table 22
Checking sequence
1
2
3
4
5
6
7 8
9
10
Mode switch position (SRV) (s) PGM ~
&
OP x/z REG xl
Z1 x2/z2
Mode code on the
9
0
1
2
E
3
4
5
6
7
display
("OEH" appears on the display when the mode switch is between two
positions and "OFH" appears when a "double code" error occurs.)
When the mode switch is turned back to the (SRV) position after
turned to the X2/Z2 position, the "Check over" print occurs and
the operationalcheck comes to an end.
If any code other than those shown above with the
"OEH" appears on the display during checking, the
check terminateswith an error print.
I
106
E–––––
exception of
operational
106
Normal print
Errorprint
–58–

Hide quick links:

Advertisement

Table of Contents
loading