8.
PRESETS LOADER
8.1 Outline
The presets loader option consists of the following devices:
0 ER-52CB S10 interface cable
0 ER-67LC (ER-52Lc)level converter
0 ER-OIFD 3.5-inch floppy disk unit
The TTL-level S10 transfer function is standard for the ER-31OO
cash register.
The ER-31OO can achieve standard (TTL-level)S10 data exchange
with another ER-31OO or the ER-OIFD through the ER-52CB, and
RS-232C S10 data exchange with a personal computer through the
ER-67LC.
This enables saving and loading of various data.
8.2 Installationprocedure
0 Installationof the ER-52CB S10 interface cable (for data
transfer between ER-31OOS)
1.
Open the S10 connector cover on the left side of the ER-31OO
by turning it backward and connect the one end of the
ER-52CB cable to the S10 connector.
2.
Connect the other end of the cable to the S10 connector of
the mating cash register.
Note: After the cable is disconnectedfrom the S10
connector,be sure to close the cover to protect the
connector.