Step Seven - Set Operating Current - Tesla HPWC Installation Manual

High power wall connector
Table of Contents

Advertisement

Step Seven - Set Operating Current

1
Turn off the power.
WARNING: RISK OF ELECTRIC
SHOCK! Before continuing, use a
voltmeter to confirm that NO POWER is
available at the service wiring or terminals.
2
Open the front cover and hold it with one
hand while completing the next step.
CAUTION: Do not release the front
cover and allow it to hang from the
ribbon cable. Doing so can damage the
ribbon cable's connectors.
Test
Mode
4
3
2
1
70A
Breaker
4
3
2
1
40A
Breaker
4
3
2
1
80A
Breaker
4
3
2
1
3
Adjust the DIP switches to set the
operating current based on the type of
breaker being used (see page 7). Use a
pointed non-conductive object such as a
plastic pen.
NOTE: Power MUST be turned off before
setting or changing DIP switches. If you set
DIP switches with the power on, not only is
it dangerous because of the risk of electric
shock (see warning above), but the
changes are not recognized.
50A
Breaker
4
3
2
1
90A
Breaker
4
3
2
1
60A
Breaker
4
3
2
1
100A
Breaker
4
3
2
1
15