Programming The Control For Phone Access

1. With at least one addressable keypad (but set to the non-addressable
mode, address 31) connected to the keypad terminals on the control,
power up the system temporarily. If you had previously connected the AC
transformer to the control panel, you need only plug in the transformer (to
120VAC outlet) to power up the system.
2. Enter the programming mode by keying the following on the keypad:
INSTALLER code (4 1 1 1) + 8 + 0.
3.
Press 26. VOICE (PHONE) MODULE ACCESS CODE.
If using a 4285 Phone module, enter the 2-digit phone access code as
follows: For first digit, enter 1–9; for second digit, enter # +11 for
# +12 for "#". Example: if desired access code is 7
and # + 11 (for ) is the second entry.
Enter "00" if not using a Phone module (this is the default).
NOTE: a "0" in either digit will disable the phone module.
4. Press 95. RING DETECTION COUNT .
Refer to the chart below and program this field accordingly.
Voice
Answering
Module
Machine
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Important
Note: If "15" is entered in field
and a 4285 Phone Module is included in the installation, you should note the
following:
When calling in from an off-premises phone (to receive a status report or execute a
command), the user should make the initial call, allow 1 to 3 rings only, and hang
up. Then call in again – the Phone Module will now seize the line, and 2 long tones
will be heard, followed by the usual voice prompt for the 2-digit phone access code.
If this procedure is not followed, Phone Module operation will not be possible.
5. Zone descriptors should also be programmed, regardless of the type of
key pads in use. If this is not done, the Phone module will not annunciate a
description of the zone(s) in alarm, trouble, etc. (the Phone module will
annunciate zone numbers only).
You can enter zone descriptors now using interactive mode 82, or later.
See the ALPHA DESCRIPTOR PROGRAMMING section for a detailed
procedure.
6. Exit the programming mode by entering 99.
Perform a preliminary check of the 4285 Phone module, as indicated next.
– 47 –
Downloading
Field 95 Programming
No
Set for value other than "0" (1–14).
This will enable the control panel to
answer the phone call. Otherwise,
it will not be possible to access the
Phone module.
No
Set for a value higher than the
number of rings for which the
answering machine is set.
Example: if the machine is set for 4
rings, use a value of 5 or higher.
This is recommended so that the
Phone module can still be accessed
if the answering machine is turned
off and does not answer the phone
call.
Yes
Set for value other than "0" (1–14).
Yes
Enter "15" to bypass the answering
machine. See Important Note below.
95 to bypass an answering machine,
, or
" "
, 7 is the first entry,