24
–
Check resistance values of the intake manifold tem-
perature sender -G42- between contacts 2 + 4.
Resistances for the coolant temperature
sender -G62-
The nominal value in field -A- applies for temperature
range 0...50 °C, nominal value in field -B- applies for tem-
perature range 50...100 °C.
Read out examples:
30 °C is within the range -A- and equals a resistance
♦
of 1500...2000 kΩ.
80 °C is in range -B- and corresponds to a resistance
♦
of 275...375 Ω.
–
Test the resistance of the coolant temperature sender
-G62- between contacts C (signal) and D (earth).
24-1
10
page
Octavia 1997
1.6 l/75 kW Engine, Fuel Injection and Ignition System
Fuel Injection System
Edition 10.04
S00.5135.52.20