Thermostat Connection (Optional); Install The Front Plate; Operation; Your First Fire - Vermont Castings SDDVT Homeowner's Installation And Operating Manual

Stardance direct vent/natural vent gas heater
Table of Contents

Advertisement

Thermostat Connection (optional)

Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Fig. 51)
�������
The Stardance is operated with the front plate in place
with the doors open or closed. To open the front doors,
pull forward to separate the magnetic catch.
CAUTION: DO NOT TOUCH DOORS WHEN
HOT!

Your First Fire

Read these instructions carefully and familiarize your-
self with the burner controls. Locate the pilot assembly,
Figure 53. Follow the lighting instructions on Page 31
exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within an hour or so, however,
you can open a window to provide fresh air to alleviate
the condition.
20012734
Maximum Run
20 feet
20 - 40 feet
up to 60 feet

Operation

��� ����� ����
����� ������
�� ��� ����� �����
����� �������
����� ����� ��������
�� ����� ������
Stardance Direct Vent/Natural Vent Gas Heater

Install the Front Plate

Hold the front plate by the window bars and lift it into
position, engaging the two steel tabs on the top corners
behind the adjacent bosses in the side plates. (Fig. 52)
Then seat the Front against the sides so the tabs at the
bottom lip engage with the notches in the stove legs.
When properly installed, the bottom of the Front Plate
cannot be pulled away from the sides without also lifting
it.
Engage steel tabs
gehind the cast
iron bosses
Control Door
Bottom tabs engage
notch in the leg.
Fig. 52 Install the front plate.
This completes assembly of the Stardance stove.
Fig. 53 Pilot assembly location.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
55. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
Follow regular maintenance procedures as described
on Page 41.
ST474
Stardance
Front
10/3/00
ST935
SDDVT
pilot location
6/07
ST474
ST935
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents