53. Remote Output Connector (VTR CONTROL,
REMOTE OUT)
The VTR control signal for the time lapse VTR is provid-
ed via this connector.
You can select on the setup menu whether to have the
VTR control signal supplied from this connector or the
RS-232C Port.
54. Alarm / Remote Control Connector (ALARM /
REMOTE)
This connector accepts the alarm signals from the asso-
ciated alarm sensor units and the control signals from
the external system.
INSTALLATIONS
The installations described below should be made by qualified service personnel or system installers.
Installing the WV-PB6164E Data Multiplex Boards
When controlling the camera with the multiplexed con-
trol data by connecting a coaxial cable, the WV-
PB6164E Data Multiplex Board must be installed in the
Video Multiplexer.
Four data multiplex boards are included with the WJ-
FS616 for cameras 1 to 4.
Please note that additional multiplex boards are avail-
able for purchase as model WV-PB6164E Data
Multiplex Boards, which includes four control boards.
Caution: Before installing boards, be sure to turn off the
Power Switch of the video multiplexer.
1. Remove the six screws on the top cover of the video
multiplexer as shown below.
Rear
55. Power Cord
56. Signal Ground Terminal (SIGNAL GND)
57. Termination Switch (TERM., OFF / ON)
58. Data Ports (DATA, OUT / IN)
2. Remove the top cover.
3. Remove the four screws on the board as shown below.
Front
4. Remove the one screw shown below. Then turn over
4
This switch is used to enable termination of the video
multiplexer's data port.
These ports are used to exchange control data with the
WV-CU550A System Controller or a PC in a system.
the printed circuit board with the front side up.