ADJUSTMENT PROCEDURE

1. Test Equipments Required
8
The following Test Equipments are required for adjust-
ment of the Video Multiplexer WJ-FS616.
8
Underscanned Colour Video Monitor
8
Video Monitor
8
Vectorscope
8
Waveform Monitor
8
Video Signal Generator
Colour Bar Signal (Set up 7.5%)
Ramp Signal (without Carrier)
Sweep Signal or Multi Burst Signal (more than 10MHz)
8
Oscilloscope
8
Frequency Counter
8
Digital Voltmeter
8
Black and White Video Camera
2. Disassembling Procedure for the
Adjustment
8
Referring to Fig. 2-1, remove five screws that secure the
Upper Cover and remove the Upper Cover.
Upper Cover
8
Referring to Fig. 2-2, remove six screws that secure the
Switch Board Ass'y and lift up the Switch Board Ass'y.
Remove six screws.
Remove five screws.
Fig. 2-1
Switch Board Ass'y
Fig. 2-2
3. Connection and Setting up for
Adjustment
3.1. Connection
8
Fig. 3-1 shows the connecting diagram for adjustment of
the WJ-FS616.
Waveform
Monitor
Rec Out
Multiscreen Out
WJ-FS616
8
Connect the Underscanned Colour Video Monitor through
the Vectorscope and Waveform Monitor to the Recording
Output Connector on the Rear Panel of the WJ-FS616.
8
Terminate the input terminal of the Underscanned Colour
Video Monitor with 75 Ω.
8
Connect the Video Monitor to the Spot Output Connector
on the Rear Panel of the WJ-FS616.
8
Connect the Signal Generator to the Camera Input
Connector 1 on the Rear Panel of the WJ-FS616.
8
Connect the prove of the Digital Voltmeter, Oscilloscope
or Frequency Counter at the desired Test Point in each
adjustment step.
3.2. Setting Up
8
This adjustment should be done after 30 minutes warm up
of the WJ-FS616.
<Initial Setting>
8
Before start to adjust should be done with this Initial
Setting as follows:
8
Turn the Power Switch off.
8
Turn the Lock Switch (SW127) on the Pocket Board to Off
position.
8
Set the Data Termination Switch (SW401) on the Modular
Board to On position.
8
Set the RS485 Termination Switch (SW602) on the
Communication Board to On position.
8
Set the Line Select Switch (SW601) on the
Communication Board to "4" position.
20
Underscanned
Vectorscope
Colour Video Monitor
75 Ω
Video Signal Generator
Video Monitor
1
Camera In
Spot Out
Fig 3-1