Clearance Requirements

Minimum Clearances to
Combustible Materials
Maintain clearance, (empty space), between combus-
tible materials and the heater as specified below for the
appropriate firebox shell being installed.
Freestanding Stove
B
Hearthmount
ST101
Min. Clrnc
4/15/99 djt
B
A: Mantel/Trim* ......................... 35" (889 mm) / 2" (51 mm)
B: Side Wall/Trim* ............................................. 2" (51 mm)
C: Rear Wall ....................................................... 0" (0 mm)
ST102
D: Max. Mantel Width ................................... 13" (330 mm)
Min. Clrnc
4/15/99 djt
Alcove Clearances
B
A: Ceiling ...................................................... 35" (889 mm)
ST103
B: Side Wall ...................................................... 2" (51 mm)
Min. Clrnc
C: Rear Wall ....................................................... 0" (0 mm)
4/15/99 djt
D: Max. Alcove Depth ................................... 13" (330 mm)
20007068
D
A
C
ST101
D
C
A
ST102
D
B
A
ST103
C
S
T
U
V
Mantel
Ref.
Shelf Depth
A
13" (330mm)
B
11¹⁄₄" (286 mm)
C
9³⁄₈" (241 mm)
D
7¹⁄₂" (191 mm)
E
5³⁄₄" (146 mm)
F
4" (102 mm)
FP599a
G
2¹⁄₄" (57 mm)
stove mantel heights
H
1" (25 mm)
9/27/99 djt

Hearth Requirements

The Freestanding Stove and Hearthmount Shell must
be installed on rigid flooring. If the appliance is installed
on any combustible surface other than wood flooring,
such as carpet or tile, a metal or wood panel must be
installed to extend the full length and width of the unit.
WARNING
• Do not install this heater in a bathroom or bed-
room.
• Installation of this heater must conform with local
codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1 / NFPA54.
• This heater creates warm air currents. These
currents move heat to wall surfaces next to the
heater. Installing the heater next to vinyl or cloth
wall coverings or operating the heater where im-
purities in the air such as tobacco smoke exist,
may discolor walls.
Do not use a blower insert, heat exchanger
insert or other accessory not approved for use
with this heater.
UVS27 Vent-Free Gas Heater
A
B
C
D
E
F
G
W
X
H
Y
Z
Mantel from
Ref.
Stove Top
S
35" (889 mm)
T
30" (762 mm)
U
25" (635 mm)
V
20" (508 mm)
W
15" (381 mm)
X
10" (254 mm)
Y
5" (127 mm)
Z
2" (51 mm)
ST599a