Catalytic Combustor - Vermont Castings 4030 - 4036 Installation And Operating Manual

Vent free gas heaters
Table of Contents

Advertisement

UVS27 Vent-Free Gas Heater

Catalytic Combustor

The combustor should be cleaned annually to ensure
optimal performance. Follow the procedure below.
Remove the Combustor Module
1. Be sure the heater is COLD.
2. Remove the screws and washers holding the com-
bustor in place. Lift combustor up and out.
Clean the Combustor Module
1. Clean the outer surface of the filter with the brush
attachment of your vacuum cleaner to remove loose
dirt.
2. Submerge the filter in a mild soapy water solution.
Rinse thoroughly with distilled water.
3. Replace in heater when dry.
Replace the Combustor Module
1. Replace combustor on top of firebox.
2. Secure with screws and washers removed earlier.
Refer to Page 11, Figure 15.