Program edit flow-chat
1.
Choose program pattern number
Parameter
PTN
2.
Setting segment n target SV
Parameter
SV_n
3.
Setting segment n TM
Parameter
TM_n
TM setting explain :
In segment_5(SEG_5) setting TM_5 =END When the program finishes segment_4(SEG_4), program end and display "END"
In segment_5(SEG_5) setting TM_5=0.00 When the program finishes segment_4(SEG_4), enter next segment, SV change
In segment_5(SEG_5) setting TM_5 =10.00 When the program finishes segment_4(SEG_4), enter next segment and
In segment_5(SEG_5) setting TM_5 =99.59 When the program finishes segment_4(SEG_4) , enter next segment and
4.
Setting segment n OUTn
Parameter
OUTn
FY operation manual
START
Set PTN
Set SV_n
Set TM_n
Set OUTn
Edit next
segment ?
YES
NO
Edit next segment SV= 0
Edit next segment TM= END
Edit next
pattern ?
YES
NO
PV/SV monitor
※ n : 1~8
END
LED display
Program pattern selection 1~18
LED display
Segment n SV (n=1~8)
LED display
Segment 1 execute time setting, this parameter
determines the link between segment and
segment or pattern and pattern
END(-1) : program end in this segment
0.00 : program step change in this segment
0.01~99.58 : program in this segment execute
time
99.59 : program continue execute in this
segment, no end
Message in segment_5(SEG_5).
suddenly.
executing TM_5 setting value.
executing continuously.
LED display
Segment n output limit (n=1~8)
Description
Description
Description
Description
Default
Level
1
Level 1
Default
Level
0
Level 1
Default
Level
0
Level 1
Default
Level
100.0
Level 1
66