Note: If multiple Touch Controllers are installed, only the Master
Controller has the ability to set the day and time.
Controller can be identified by the letter "M" in the bottom right hand
corner on the home screen.
3.3 Installer Setup
Interconnection of Heating and/or Cooling appliance(s) shall be
complete prior to entering INSTALLER SETUP. If your system
contains one Touch Controller, one heater (no zoning) and/or
one evaporative cooler no network parameters need to change.
To enter installer setup, enter PIN 5240 and press 'OK', refer
Diagram 15.
Diagram 15: Touch Controller INSTALLER SETUP
When accessing the CUSTOM SETUP screen through the Master
The Master
Touch Controller the following options may be available, and is
dependent on connected appliances.
1. Reset the identification of the Touch Controller (only required
if more than one Touch Controller is fitted).
2. Access the installer parameters (system functionality).
3. Access the evaporative cooler installer parameters if an
evaporative cooler exists on the system.
4. Access the heater installer parameters if a heater exists on the
system, refer Diagram 16.
Diagram 16: Master Touch Controller CUSTOM SETUP
12