SERIAL PLATE LOCATION

The serial plate is located on the interior top,
left side of the merchandiser. It contains all
pertinent information such as model, serial
number, amperage rating, refrigerant type and
charge. This information will be needed to
install, service or order parts for the merchandis-
er.
Serial Plate

SEALING MERCHANDISER TO FLOOR

If required by local sanitary codes, or if the
customer desires, merchandisers may be sealed
to the floor using a vinyl cove base trim. The
size needed will depend on how much varia-
tion there is in the floor, from one end of the
merchandiser to the other. Sealing of the lower
front and rear panels on self contained mod-
els may hamper their removal for servicing or
maintenance of the condensing unit.
NOTE: Do not allow trim to cover any intake
or discharge grilles located in the lower front
panel.
P/N 3003960_A

REFRIGERATION UNIT ACCESS

The lower front panel may be removed by
removing screw at bottom and lifting the panel
straight upward and over the tabs on which it
is hanging. The panel is installed by reversing the
above procedure.
Ensure lower front panel is flat against the
floor when installed to prevent air circulation
problems for self contained merchandisers.
Front Panel
U.S. & Canada 1-800-922-1919 • Mexico 1 800-890-2900 • www.hussmann.com
Safe-NET III Display
Lift up and
out to remove
access panel
Safe-NET III display is
mounted on left side of
access panel. Be careful not
to detach Safe-NET III cable
from display when removing
access panel.
Safe-NET III
Display